Antibody Pairs Support Pack 2
Instruction manual
First Edition (Revised on April, 2016)
[PRODUCT INFORMATION]
Antibody Pairs Support Pack is intended to use together with Antibody Pairs for ELISA/CLIA kit preparation. This pack provides reagents for preparation of 10 Competitive ELISA/CLIA plates. All reagents should be used at room temperature and the pack is intended for research purposes only.
[REAGENTS AND MATERIALS PROVIDED]
Reagents | Quantity |
Coating Buffer | 1 bottle of powder |
Blocking Buffer | 1 bottle of powder |
Standard Diluent | 1 bottle of powder |
Biontin-labeled Competitor Diluent | 1 bottle of powder |
Streptavidin-HRP Diluent | 1 bottle of powder |
Wash Buffer | 2 bottles of powder |
Streptavidin-HRP | 1 bottle, 1.2ml |
Substrate Solution | 2 bottles, 48ml each |
Stop Solution | 2 bottles, 30ml each |
[APPLICATIONS]
Reagents | Applications |
Coating Buffer | Used for coating antibody on the wells of 96-well strip plate. Prepare a working solution by diluting the Coating Buffer with deionized or distilled water before the experiment. 1 bottle of Coating Buffer can be used for preparing 220ml working solution. |
Blocking Buffer | Used for blocking of unspecific binding sites of the plate. Prepare a working solution by diluting the Blocking Buffer with deionized or distilled water before the experiment. 1 bottle of Blocking Buffer can be used for preparing 240ml working solution. |
Standard Diluent | Used for dilution of Standard. Prepare a working solution by diluting the Standard Diluent with deionized or distilled water before the experiment. 1 bottle of Standard Diluent can be used for preparing 160ml working solution. |
Biontin-labeled Competitor Diluent | Used for dilution of Biotin-labeled Competitor. Prepare a working solution by diluting the Biotin-labeled Competitor Diluent with deionized or distilled water before the experiment. 1 bottle can be used for preparing 120ml working solution. |
Streptavidin-HRP Diluent | Used for dilution of Streptavidin-HRP. Prepare a working solution by diluting the Strepavidin-HRP Diluent with deionized or distilled water before the experiment. 1 bottle can be used for preparing 120ml working solution. |
Wash Buffer | For plate washing. Prepare a working solution by diluting the Wash Buffer with deionized or distilled water before the experiment. 1 bottle can be used for preparing 2000mL working solution. |
Streptavidin-HRP | Strepavidin-HRP can specifically bind biotinylated antigens or antibodies. Prepare a working solution by diluting the Streptavidin-HRP with Streptavidin-HRP Diluent working solution. The dilution ratio was 1:100. 1 bottle can be used for preparing 120ml working solution. |
Substrate Solution | Used for chromogenic substrate. |
Stop Solution | Used for stopping chromogenic reaction. |
NOTE: *All of the working solutions should be clear.
*If the working solution is prepared, please store at 2-8ºC.
[STORAGE]
Streptavidin-HRP should be stored at -20℃, others are valid for 6 months at 4℃. Store diluted (reconstituted powder) or working solutions at 4 ℃ for up to one week for use in subsequent experiments.
[IMPORTANT NOTES]
Appropriate care should be exercised when using these reagents, including gloves, glasses, lab coats, and good laboratory procedures.