CLIA Kit for Antidiuretic Hormone (ADH)
ARVP; AVP; VP; Arginine Vasopressin; Arg-Vasopressin; Antidiuretic Hormone; Diabetes Insipidus; Neurohypophyseal; Argipressin
- Product No.CCB139Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range11.72-3,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 4.28pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 605
For more details, please contact local distributors! US$ 864 US$ 3888 US$ 7344 US$ 60480
Specificity
This assay has high sensitivity and excellent specificity for detection of Antidiuretic Hormone (ADH).
No significant cross-reactivity or interference between Antidiuretic Hormone (ADH) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Antidiuretic Hormone (ADH) and the recovery rates were calculated by comparing the measured value to the expected amount of Antidiuretic Hormone (ADH) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 85-95 | 90 |
EDTA plasma(n=5) | 80-95 | 81 |
heparin plasma(n=5) | 92-104 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antidiuretic Hormone (ADH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antidiuretic Hormone (ADH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Antidiuretic Hormone (ADH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-98% | 96-103% | 91-102% | 95-103% |
EDTA plasma(n=5) | 98-105% | 92-105% | 91-99% | 84-96% |
heparin plasma(n=5) | 80-90% | 95-102% | 89-103% | 89-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Neuroscience | Angiotensin II Type 1a Receptors in the Subfornical Organ Modulate Neuroinflammation in the Hypothalamic Paraventricular Nucleus in Heart Failure Rats Pubmed:29684507 |
American Journal of Physiology-Renal Physiology | Chronic nicotine exposure reduces klotho expression and triggers different renal and hemodynamic responses in -haploinsufficient mice Pubmed:29363324 |
The Eurasian Journal of Medicine | Effects of Conivaptan versus Mannitol on Post-Ischemic Brain Injury and Edema |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
MEB139Mu | Mini Samples ELISA Kit for Antidiuretic Hormone (ADH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEB139Mu | ELISA Kit for Antidiuretic Hormone (ADH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCB139Mu | CLIA Kit for Antidiuretic Hormone (ADH) | Chemiluminescent immunoassay for Antigen Detection. |
LMB139Mu | Multiplex Assay Kit for Antidiuretic Hormone (ADH) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB139Mu11 | ELISA Kit DIY Materials for Antidiuretic Hormone (ADH) | Main materials for "Do It (ELISA Kit) Yourself". |