Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
CLIA Kit for Arginine (Arg)
(S)-2-Amino-5-Guanidinopentanoic Acid
- Product No.CCB938Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range390.6-100,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 146.9ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 571
For more details, please contact local distributors! US$ 816 US$ 3672 US$ 6936 US$ 57120
Specificity
This assay has high sensitivity and excellent specificity for detection of Arginine (Arg).
No significant cross-reactivity or interference between Arginine (Arg) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Arginine (Arg) and the recovery rates were calculated by comparing the measured value to the expected amount of Arginine (Arg) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 90-104 | 96 |
EDTA plasma(n=5) | 98-105 | 102 |
heparin plasma(n=5) | 88-102 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Arginine (Arg) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Arginine (Arg) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Arginine (Arg) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-98% | 99-105% | 78-99% | 90-102% |
EDTA plasma(n=5) | 94-101% | 79-103% | 79-90% | 79-94% |
heparin plasma(n=5) | 83-91% | 80-88% | 81-95% | 98-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
The Journal of Physiology | Asymmetric dimethylarginine (ADMA) elevation and arginase up-regulation contribute toendothelial dysfunction related to insulin resistance in rats and morbidly obese humans. pubmed:26840628 |
Cell Death & Disease | α-ketoglutarate dehydrogenase inhibition counteracts breast cancer-associated lung metastasis Pubmed:29988033 |
Nutrition, Metabolism and Cardiovascular Diseases | Arginine bioavailability and endothelin-1 system in the regulation of vascular function of umbilical vein endothelial cells from intrauterine growth restricted newborns Doi: 10.1016/j.numecd.2018.09.002 |
Nitric Oxide | Effects of dietary nitrate supplementation on microvascular physiology at 4559 m altitude–A randomised controlled trial (Xtreme Alps) Pubmed: 31604146 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPB938Ge11 | BSA Conjugated Arginine (Arg) | Immunogen; SDS-PAGE; WB. |
CPB938Ge21 | OVA Conjugated Arginine (Arg) | Immunogen; SDS-PAGE; WB. |
PAB938Ge01 | Polyclonal Antibody to Arginine (Arg) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
CEB938Ge | ELISA Kit for Arginine (Arg) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCB938Ge | CLIA Kit for Arginine (Arg) | Chemiluminescent immunoassay for Antigen Detection. |
LMB938Ge | Multiplex Assay Kit for Arginine (Arg) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB938Ge11 | ELISA Kit DIY Materials for Arginine (Arg) | Main materials for "Do It (ELISA Kit) Yourself". |