ELISA Kit for Motilin (MTL)

MLN; MAP; Promotilin; Motilin-associated peptide

Specificity

This assay has high sensitivity and excellent specificity for detection of Motilin (MTL).
No significant cross-reactivity or interference between Motilin (MTL) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Motilin (MTL) and the recovery rates were calculated by comparing the measured value to the expected amount of Motilin (MTL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-97 93
EDTA plasma(n=5) 98-105 102
heparin plasma(n=5) 89-96 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Motilin (MTL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Motilin (MTL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Motilin (MTL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-95% 80-104% 78-101% 84-98%
EDTA plasma(n=5) 89-96% 82-96% 95-105% 95-102%
heparin plasma(n=5) 96-104% 90-103% 84-97% 94-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
世界华人消化杂志 清醒状态下热射病大鼠胃肠动力与胃泌素、胃动素的变化 Wjgnet:Source
Sci Rep. Using the "target constituent removal combined with bioactivity assay" strategy to investigate the optimum arecoline content in charred areca nut. pubmed:28054652
Applied Biological Chemistry Positive enhancement of Lactobacillus fermentum HY01 on intestinal movements of mice having constipation 10.1007/s13765-017-0327-3
Biomed Research International Colonic Transit Time and Gut Peptides in Adult Patients with Slow and Normal Colonic Transit Constipation pubmed:29082242
Evidence-Based Complementary and Alternative Medicine Home-Based Transcutaneous Neuromodulation Improved Constipation via Modulating Gastrointestinal Hormones and Bile Acids Pubmed:29853946
The American Journal of the Medical Sciences The Relations Among Serum Ghrelin, Motilin and Gastric Emptying and Autonomic Function in Autoimmune Gastritis Pubmed:29753372
NEUROGASTROENTEROLOGY AND MOTILITY Integrative effects of transcutaneous electrical acustimulation on abdominal pain, gastrointestinal motility, and inflammation in patients with early‐stage acute … 34536258
Evid Based Complement Alternat Med The Inhibitory Effects of Naringin in a Rat Model of Postoperative Intraperitoneal Adhesion Formation Pubmed:35069760
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
CEA575Mu ELISA Kit for Motilin (MTL) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA575Mu Multiplex Assay Kit for Motilin (MTL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA575Mu11 ELISA Kit DIY Materials for Motilin (MTL) Main materials for "Do It (ELISA Kit) Yourself".