ELISA Kit for Angiotensin I (AngI)

Ang-I; Angiotensin-1

Specificity

This assay has high sensitivity and excellent specificity for detection of Angiotensin I (AngI).
No significant cross-reactivity or interference between Angiotensin I (AngI) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Angiotensin I (AngI) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin I (AngI) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-104 89
EDTA plasma(n=5) 95-103 98
heparin plasma(n=5) 94-102 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin I (AngI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin I (AngI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin I (AngI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-97% 80-90% 84-99% 91-99%
EDTA plasma(n=5) 96-105% 82-90% 88-99% 86-93%
heparin plasma(n=5) 90-102% 90-104% 94-102% 82-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1 Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Reagent Diluent 1×300µL Stop Solution 1×6mL
TMB Substrate 1×9mL Instruction manual 1
Wash Buffer (30 × concentrate) 1×20mL

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Inflammopharmacology Evening primrose oil and celecoxib inhibited pathological angiogenesis, inflammation, and oxidative stress in adjuvant-induced arthritis: novel role of angiopoietin-1 Pubmed: 24664592
Clinical Nutrition Protein malnutrition impairs bone marrow endothelial cells affecting hematopoiesis Pubmed: 31326233
Journal of Alzheimers Disease Cerebrospinal Fluid Changes in the Renin-Angiotensin System in Alzheimer's Disease Pubmed: 31594235
Dikkat Eksikliği Hiperaktivite Bozukluğu Tanısı Olan Anjiyotensin I, II, III, Alamandin peptid, Anjiyotensin Dönüştürücü Enzim (ACE), NADPH Oksidaz Enzim Serum …
The Effect of Angiotensin-Converting Enzyme Gene Polymorphisms in the Coronary Slow Flow Phenomenon at South Sumatra, Indonesia Population
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
CEA811Ra ELISA Kit for Angiotensin I (AngI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA811Ra Multiplex Assay Kit for Angiotensin I (AngI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA811Ra11 ELISA Kit DIY Materials for Angiotensin I (AngI) Main materials for "Do It (ELISA Kit) Yourself".