Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Acetylcholine (ACH)
- Product No.CEA912Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range12.35-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.06pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 557
For more details, please contact local distributors! US$ 796 US$ 3580 US$ 6763 US$ 55692
Specificity
This assay has high sensitivity and excellent specificity for detection of Acetylcholine (ACH).
No significant cross-reactivity or interference between Acetylcholine (ACH) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Acetylcholine (ACH) and the recovery rates were calculated by comparing the measured value to the expected amount of Acetylcholine (ACH) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-98 | 89 |
EDTA plasma(n=5) | 89-98 | 94 |
heparin plasma(n=5) | 83-97 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Acetylcholine (ACH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Acetylcholine (ACH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Acetylcholine (ACH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-102% | 97-105% | 84-91% | 83-91% |
EDTA plasma(n=5) | 84-104% | 83-93% | 80-90% | 78-102% |
heparin plasma(n=5) | 80-91% | 96-104% | 86-101% | 81-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Neurosci Bull | Combined administration of D-galactose and aluminium induces Alzheimer-like lesions in brain PubMed: 21614097 |
Molecular Neurobiology | Neuroprotective effects of simvastatin and Cilostazol in L-methionine-induced vascular dementia in rats pubmed:27544235 |
Turk Kardiyol Dern Ars. | Effect of statins on sirtuin 1 and endothelial nitric oxide synthase expression in young patients with a history of premature myocardial infarction Pubmed:29664427 |
JOURNAL OF LIPID RESEARCH | Carotid baroreceptor stimulation in obese rats affects white and brown adipose tissues differently in metabolic protection Pubmed: 31126973 |
NEUROPHARMACOLOGY | Caffeic acid phenethyl ester counteracts doxorubicin-induced chemobrain in Sprague-Dawley rats: Emphasis on the modulation of oxidative stress and … Pubmed: 33011510 |
FASEB JOURNAL | Irradiation of carotid baroreceptor with low‐intensity pulsed ultrasound exerts different metabolic protection in perirenal, epididymal white adipose tissue and … Pubmed: 32954574 |
Exp Eye Res | Autonomic nervous system receptor-mediated regulation of mast cell degranulation modulates the inflammation after corneal epithelial abrasion Pubmed:35421396 |
SAUDI J BIOL SCI | Aqueous Ajwa dates seeds extract improves memory impairment in type-2 diabetes mellitus rats by reducing blood glucose levels and enhancing brain … Pubmed:35531250 |
Arq. Bras. Med. Vet. Zootec | Study on the mechanisms of Suaeda rigida polysaccharides on the heart inhibition and skeletal muscle promotion in the frog |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPA912Ge11 | BSA Conjugated Acetylcholine (ACH) | Immunogen; SDS-PAGE; WB. |
CPA912Ge21 | OVA Conjugated Acetylcholine (ACH) | Immunogen; SDS-PAGE; WB. |
PAA912Ge01 | Polyclonal Antibody to Acetylcholine (ACH) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
LAA912Ge71 | Biotin-Linked Polyclonal Antibody to Acetylcholine (ACH) | WB; IHC; ICC. |
CEA912Ge | ELISA Kit for Acetylcholine (ACH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA912Ge | Mini Samples ELISA Kit for Acetylcholine (ACH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA912Ge | Multiplex Assay Kit for Acetylcholine (ACH) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA912Ge11 | ELISA Kit DIY Materials for Acetylcholine (ACH) | Main materials for "Do It (ELISA Kit) Yourself". |