Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Vitamin C (VC)
AA; L-Ascorbic Acid; Ascorbate
- Product No.CEA913Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range493.8-40,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 177.4ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 557
For more details, please contact local distributors! US$ 796 US$ 3580 US$ 6763 US$ 55692
Specificity
This assay has high sensitivity and excellent specificity for detection of Vitamin C (VC).
No significant cross-reactivity or interference between Vitamin C (VC) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Vitamin C (VC) and the recovery rates were calculated by comparing the measured value to the expected amount of Vitamin C (VC) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 89-99 | 95 |
EDTA plasma(n=5) | 99-105 | 102 |
heparin plasma(n=5) | 78-94 | 84 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitamin C (VC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitamin C (VC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vitamin C (VC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-105% | 94-103% | 79-99% | 78-97% |
EDTA plasma(n=5) | 85-97% | 80-99% | 80-94% | 89-103% |
heparin plasma(n=5) | 88-96% | 96-104% | 78-89% | 79-93% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
BioMed Research International | Salivary 1, 5-Anhydroglucitol and Vitamin Levels in Relation to Caries Risk in Children |
Vitamin A, C, D, E and B12 Levels in Leprosy: A Case Control Study | |
Nutrients | Vitamin C¡ªSources, Physiological Role, Kinetics, Deficiency, Use, Toxicity, and Determination 33668681 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPA913Ge11 | BSA Conjugated Vitamin C (VC) | Immunogen; SDS-PAGE; WB. |
CPA913Ge21 | OVA Conjugated Vitamin C (VC) | Immunogen; SDS-PAGE; WB. |
PAA913Ge01 | Polyclonal Antibody to Vitamin C (VC) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
LAA913Ge71 | Biotin-Linked Polyclonal Antibody to Vitamin C (VC) | WB; IHC; ICC. |
MAA913Ge21 | Monoclonal Antibody to Vitamin C (VC) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
CEA913Ge | ELISA Kit for Vitamin C (VC) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA913Ge | Multiplex Assay Kit for Vitamin C (VC) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA913Ge11 | ELISA Kit DIY Materials for Vitamin C (VC) | Main materials for "Do It (ELISA Kit) Yourself". |