Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Spermidine (SMD)
- Product No.CEX053Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range781.25-200,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 274.31pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 623
For more details, please contact local distributors! US$ 890 US$ 4005 US$ 7565 US$ 62300
Specificity
This assay has high sensitivity and excellent specificity for detection of Spermidine (SMD).
No significant cross-reactivity or interference between Spermidine (SMD) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Spermidine (SMD) and the recovery rates were calculated by comparing the measured value to the expected amount of Spermidine (SMD) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-95 | 91 |
EDTA plasma(n=5) | 97-105 | 101 |
heparin plasma(n=5) | 95-102 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Spermidine (SMD) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Spermidine (SMD) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Spermidine (SMD) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 90-98% | 82-103% | 92-104% | 90-98% |
EDTA plasma(n=5) | 80-95% | 91-99% | 81-101% | 80-103% |
heparin plasma(n=5) | 95-105% | 97-105% | 81-101% | 85-92% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Nature | Metabolites released from apoptotic cells act as tissue messengers Pubmed: 32238926 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CEX053Ge | ELISA Kit for Spermidine (SMD) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCX053Ge | CLIA Kit for Spermidine (SMD) | Chemiluminescent immunoassay for Antigen Detection. |
LMX053Ge | Multiplex Assay Kit for Spermidine (SMD) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |