Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay)
ACV-A; Activin Beta A Beta A Homodimer
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA001Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 405
US$ 420
US$ 443
US$ 475
US$ 506
US$ 552
US$ 622
Result
For more details, please contact local distributors! US$ 778 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-105 | 101 |
EDTA plasma(n=5) | 86-102 | 91 |
heparin plasma(n=5) | 94-103 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-97% | 93-104% | 97-105% | 96-104% |
EDTA plasma(n=5) | 96-103% | 90-104% | 88-97% | 99-105% |
heparin plasma(n=5) | 88-104% | 84-96% | 96-105% | 79-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:ACVA) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
13 | Secretory Products From Epicardial Adipose Tissue of Patients With Type 2 Diabetes Mellitus Induce Cardiomyocyte Dysfunction Ahajournals: Source |
J. Pharmacogn | Article: Hksobf_2015_V46N2_167 |
United States Patent Application | Methods for Diagnosis and Treatment of Concussion or Brain Injury 2016:0103140 |
BMC Cancer. | Activins and their related proteins in colon carcinogenesis: insights from early and advanced azoxymethane rat models of colon cancer. pubmed:27835986 |
Basic Clin Pharmacol Toxicol. | Magnolol Attenuates Concanavalin A-induced Hepatic Fibrosis, Inhibits CD4+ T Helper 17 (Th17) Cell Differentiation and Suppresses Hepatic Stellate Cell Activation: Blockade of Smad3/Smad4 Signalling. pubmed:28032440 |
Basic & Clinical Pharmacology & Toxicology | Magnolol Attenuates Concanavalin A-induced Hepatic Fibrosis, Inhibits CD4 + T Helper 17(Th17) Cell Differentiation and Suppresses Hepatic Stellate Cell Activation: Blockade of Smad3/Smad4 Signalling doi:10.1111 |
Journal of Immunology | MicroRNA-27b Modulates Inflammatory Response and Apoptosis during Mycobacterium tuberculosis Infection Pubmed:29661829 |
Journal of Vascular Surgery | Expression of platelet-derived growth factor B is upregulated in patients with thoracic aortic dissection Pubmed:29685513 |
Acta Biochimica et Biophysica Sinica | Toxic effects of arsenic trioxide on protoscoleces through ROS production, and Ca-ER stress-dependent apoptosis 10.1093:abbs |
Poultry Science | The effect of raw and fermented rapeseed cake on the metabolic parameters, immune status, and intestinal morphology of turkeys Pubmed:29917099 |
Food Bioscience | Characterization of Phospholipids from Pacific Saury () Viscera and Their Neuroprotective Activity 10.1016:j.fbio.2018.06.002 |
Current Analytical Chemistry | Single Wall Carbon Nanotube and Magnetic Bead Based Electrochemical Immunosensor for Sensitive Detection of Salivary Secretory Immunoglobulin A 10.2174:2211556006666170525161225 |
Journal of Veterinary Internal Medicine | FRIDAY, NOVEMBER 3, 2017 11.30-12.0 BALLROOM AB : |
Universal Journal of Pharmaceutical Research | SEROPREVALENCE OF ANTI-MANNOSE BINDING LECTIN AUTOANTIBODIES IN PATIENTS WITH RHEUMATOID ARTHRITIS IN SANA'A CITY-YEMEN 10.22270:ujpr.v3i2.138 |
Involvement of RBP4 in diabetic atherosclerosis and the role of vitamin D intervention : | |
Clin Oral Investig. | Gingival crevicular fluid levels of human beta-defensin-1 in type 2 diabetes mellitus and periodontitis Pubmed:29713888 |
Myocardial fibrosis in hypertrophic cardiomyopathy : | |
TELLING TRANSVERSAL COMPETENCES… TO BE PROFESSIONALLY PROMOTED : | |
Protein biomarker panels for detecting colorectal cancer and advanced adenoma : | |
Endothelotropic activity of 4-hydroxy-3, 5-di-tret-butylcinnamic acid in the conditions of experimental cerebral ischemia : | |
Silencing of the CSNK2β gene by siRNA inhibits invasiveness and growth of MDA-MB-231 cells 10.1101:311092 | |
Duchenne Muscular Dystrophy | Flow Cytometry-Defined CD49d Expression in Circulating T-Lymphocytes Is a Biomarker for Disease Progression in Duchenne Muscular Dystrophy Pubmed:29067667 |
S | S S |
P | P P |
D | D D |
h | h h |
O | O O |
M | M M |
E | E E |
I | I I |
B | B B |
T | T T |
N | N N |
L | L L |
J | J J |
Journal of Geriatric Oncology | Serum biomarkers for predicting overall survival and early mortality in older patients with metastatic solid tumors Pubmed: 30952517 |
clinica chimica acta | The performances of serum activins and follistatin in the diagnosis of ectopic pregnancy: A prospective case-control study Pubmed: 31647905 |
hindawi | The Association between the Activin A Serum Level and Carotid Intima-Media Thickness in Chronic Kidney Disease Patients |
Pathology & Oncology Research | Profiling Activins and Follistatin in Colorectal Cancer According to Clinical Stage, Tumour Sidedness and Smad4 Status 34867090 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
CEA001Mu | ELISA Kit for Activin A (ACVA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA001Mu | Multiplex Assay Kit for Activin A (ACVA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |