Multiplex Assay Kit for Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

NAP3; GRO1; GROa; GRO-A; MGSA-A; NAP3; SCYB1; Chemokine C-X-C-Motif Ligand 1; Melanoma Growth Stimulating Activity Alpha; Fibroblast Secretory Protein

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-89 84
EDTA plasma(n=5) 93-105 101
heparin plasma(n=5) 82-97 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-94% 80-101% 78-101% 95-104%
EDTA plasma(n=5) 80-97% 79-105% 98-105% 80-93%
heparin plasma(n=5) 80-90% 80-103% 83-102% 89-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CXCL1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
中国眼耳鼻喉科杂志 白细胞介素10 上调表达对家兔慢性细菌性鼻窦炎黏膜创伤修复的影响 article:11593
Scientific Reports Epidermal CD147 expression plays a key role in IL-22-induced psoriatic dermatitis. pubmed:28272440
Phytotherapy Research Total flavonoids from sea buckthorn ameliorates lipopolysaccharide/cigarette smoke‐induced airway inflammation Pubmed: 31209984
Frontiers in Oncology CXCL1 as an Unfavorable Prognosis Factor Negatively Regulated by DACH1 in Non-small Cell Lung Cancer Pubmed: 31998654
Phytomedicine Baohuoside I suppresses breast cancer metastasis by downregulating the tumor-associated macrophages/CXC motif chemokine ligand 1 pathway Pubmed: 32911383
Lab Invest Extracellular cold-inducible RNA-binding protein regulates neutrophil extracellular trap formation and tissue damage in acute pancreatitis Pubmed: 32709888
Phytomedicine Aiduqing formula suppresses breast cancer metastasis via inhibiting CXCL1-mediated autophagy
Cell Commun Signal Aiduqing formula inhibits breast cancer metastasis by suppressing TAM/CXCL1-induced Treg differentiation and infiltration 34461944
Viruses Interleukin-10-Mediated Lymphopenia Caused by Acute Infection with Foot-and-Mouth Disease Virus in Mice 34960627
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA041Hu01 Active Chemokine (C-X-C Motif) Ligand 1 (CXCL1) Cell culture; Activity Assays.
RPA041Hu01 Recombinant Chemokine (C-X-C Motif) Ligand 1 (CXCL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA041Hu01 Polyclonal Antibody to Chemokine (C-X-C Motif) Ligand 1 (CXCL1) WB; ICC; IHC-P; IHC-F; ELISA.
LAA041Hu71 Biotin-Linked Polyclonal Antibody to Chemokine (C-X-C Motif) Ligand 1 (CXCL1) WB; IHC; ICC.
MAA041Hu22 Monoclonal Antibody to Chemokine (C-X-C Motif) Ligand 1 (CXCL1) WB; IHC; ICC; IP.
SEA041Hu ELISA Kit for Chemokine (C-X-C Motif) Ligand 1 (CXCL1) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA041Hu Mini Samples ELISA Kit for Chemokine (C-X-C Motif) Ligand 1 (CXCL1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA041Hu CLIA Kit for Chemokine (C-X-C Motif) Ligand 1 (CXCL1) Chemiluminescent immunoassay for Antigen Detection.
LMA041Hu Multiplex Assay Kit for Chemokine (C-X-C Motif) Ligand 1 (CXCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA041Hu01 ELISA Kit DIY Materials for Chemokine (C-X-C Motif) Ligand 1 (CXCL1) Main materials for "Do It (ELISA Kit) Yourself".