Multiplex Assay Kit for Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay)

CDF; D-FACTOR; HILDA; MLPLI; Cholinergic Differentiation Factor; Differentiation-Stimulating Factor; Melanoma-Derived LPL Inhibitor; Emfilermin

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-103 92
EDTA plasma(n=5) 96-103 99
heparin plasma(n=5) 91-99 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-101% 78-90% 80-103% 87-98%
EDTA plasma(n=5) 87-95% 84-99% 88-102% 88-99%
heparin plasma(n=5) 81-104% 97-105% 92-103% 99-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LIF) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
British Journal of Anaesthesia Leukemia inhibitory factor (LIF) potentiates antinociception activity and inhibits tolerance induction of opioids pubmed:28077540
Biological Rhythm Research A study of altered cytokine rhythms associated with successful implantation in cows 10.1080/09291016.2017.1361159
Integrated analysis of cancer stem cells-associated lncRNA-miRNA-mRNA network for ovarian cancer via microarray and Gene Expression Omnibus database
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA085Hu61 Active Leukemia Inhibitory Factor (LIF) Cell culture; Activity Assays.
RPA085Hu01 Recombinant Leukemia Inhibitory Factor (LIF) Positive Control; Immunogen; SDS-PAGE; WB.
EPA085Hu61 Eukaryotic Leukemia Inhibitory Factor (LIF) Positive Control; Immunogen; SDS-PAGE; WB.
APA085Hu01 Active Leukemia Inhibitory Factor (LIF) Cell culture; Activity Assays.
PAA085Hu01 Polyclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC
MAA085Hu22 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
MAA085Hu21 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
MAA085Hu23 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
MAA085Hu24 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
SEA085Hu ELISA Kit for Leukemia Inhibitory Factor (LIF) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA085Hu Multiplex Assay Kit for Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.