Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay)
CCL5; SCYA5; SISd; EoCP; Chemokine C-C-Motif Ligand 5; Eosinophil Chemotactic Cytokine; T-cell Specific Protein p288; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 5
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA116Gu
- Organism SpeciesCavia (Guinea pig ) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell culture supernates and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 449
US$ 467
US$ 492
US$ 527
US$ 562
US$ 613
US$ 691
Result
For more details, please contact local distributors! US$ 864 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 84-98 | 90 |
EDTA plasma(n=5) | 96-105 | 101 |
heparin plasma(n=5) | 87-104 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 97-105% | 89-102% | 93-101% | 85-94% |
EDTA plasma(n=5) | 78-105% | 97-104% | 90-97% | 81-88% |
heparin plasma(n=5) | 91-99% | 79-98% | 79-103% | 89-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:RANTES) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
J Thorac Dis.? | Anti-endothelial cell antibodies in connective tissue diseases associated with pulmonary arterial hypertension Pubmed:Pmc4015009 |
Pharmacol Rep.? | Comparison of chemokines (CCL-5 and SDF-1), chemokine receptors (CCR-5 and CXCR-4) and IL-6 levels in patients with different severities of depression Pubmed:25150002 |
Pharmacological Reports | The MCP-1, CCL-5 and SDF-1 chemokines as pro-inflammatory markers in generalized anxiety disorder and personality disorders Pubmed:25560580 |
Pharmacological Reports | Serum concentrations of chemokines (CCL-5 and CXCL-12), chemokine receptors (CCR-5 and CXCR-4), and IL-6 in patients with posttraumatic stress disorder and avoidant personality disorder PubMed: 26481549 |
Veterinary Parasitology | Expression of adhesion molecules, chemokines and matrix metallo- proteinases (MMPs) in viable and degenerating stage of Taenia solium metacestode in swine neurocysticercosis PubMed: 26412140 |
Pharmacological Reports | A study of chemokines, chemokine receptors and interleukin-6 in patients with panic disorder, personality disorders and their co-morbidity Pubmed:27208878 |
PLoS One. | Diacerein inhibits the pro-atherogenic & pro-inflammatory effects of IL-1 on human keratinocytes & endothelial cells. pubmed:28323859 |
Experimental Parasitology | Adhesion molecules, chemokines and matrix metallo-proteinases response after albendazole and albendazole plus steroid therapy in swine neurocysticercosis pubmed:28821422 |
National Natural Scientific | Role of Gut-Derived Endotoxin on Type I Collagen Production in the Rat Pancreas after Chronic Alcohol Exposure pubmed:29121396 |
Journal of Immunology Research | Therapeutic Potential of Pien Tze Huang on Experimental Autoimmune Encephalomyelitis Rat Pubmed:29682587 |
Rheumatology international | Serum levels of selected cytokines [interleukin (IL)-17A, IL-18, IL-23] and chemokines (RANTES, IP10) in the acute phase of immunoglobulin A vasculitis in … Pubmed: 31468124 |
Cell Death & Disease | CCL5 derived from tumor-associated macrophages promotes prostate cancer stem cells and metastasis via activating β-catenin/STAT3 signaling Pubmed: 32300100 |
Medicina | Assessment of the RANTES Level Correlation and Selected Inflammatory and Pro-Angiogenic Molecules Evaluation of Their Influence on CRC Clinical Features: A … Pubmed:35208526 |
Journal of Immunology Research | Ebosin Attenuates the Inflammatory Responses Induced by TNF-α through Inhibiting NF-κB and MAPK Pathways in Rat Fibroblast-Like Synoviocytes Pubmed:35340587 |
Reseach square | Assessment of selected interleukins (IL-6, IL-17A, IL-18, IL-23) and chemokines (RANTES, IP-10) in children with acute and chronic urticaria |
Catalog No. | Related products for research use of Cavia (Guinea pig ) Organism species | Applications (RESEARCH USE ONLY!) |
RPA116Gu01 | Recombinant Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA116Gu01 | Polyclonal Antibody to Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) | WB; IHC; ICC; IP. |
MAA116Gu21 | Monoclonal Antibody to Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) | WB; IHC; ICC; IP. |
SEA116Gu | ELISA Kit for Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA116Gu | Multiplex Assay Kit for Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |