Multiplex Assay Kit for Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay)

KITLG; MGF; SF; KL1; Kitl; FPH2; Kit-Ligand; Steel Factor; Mast Cell Growth Factor; Steel factor; Familial Progressive Hyperpigmentation 2

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-104 91
EDTA plasma(n=5) 94-105 98
heparin plasma(n=5) 96-103 101
sodium citrate plasma(n=5) 83-97 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 87-104% 81-105% 95-103%
EDTA plasma(n=5) 85-103% 81-96% 93-105% 86-96%
heparin plasma(n=5) 78-103% 83-101% 81-90% 79-102%
sodium citrate plasma(n=5) 97-104% 84-98% 89-103% 93-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:SCF) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Archives of Gynecology and Obstetrics Effect of ovarian stimulation with recombinant follicle-stimulating hormone, gonadotropin-releasing hormone agonist and antagonists, on follicular fluid stem cell factor and serum urocortin 1 levels on the day of oocyte retrieval Pubmed: 23801011
Medicine (Baltimore) An Attempt to Evaluate Selected Aspects of “Bone–Fat Axis” Function in Healthy Individuals and Patients With Pancreatic Cancer PubMed: 26266370
Tumor Biology Hypoxia-induced secretion of IL-13 from adipose-derived mesenchymal stem cell promotes growth and cancer stem cell properties of Burkitt lymphoma PubMed: 26695151
Molecular Neurobiology Middle-Aged Diabetic Females and Males Present Distinct Susceptibility to Alzheimer Disease-like Pathology. pubmed:27730513
Oncotarget Nucleoside reverse transcriptase inhibitor-induced rat oocyte dysfunction and low fertility mediated by autophagy Pubmed:29423092
Journal of Environmental Research and Public Health Effects of 220 MHz Pulsed Modulated Radiofrequency Field on the Sperm Quality in Rats Pubmed: 30974849
Catalog No. Related products for research use of Canis familiaris; Canine (Dog) Organism species Applications (RESEARCH USE ONLY!)
APA120Ca61 Active Stem Cell Factor (SCF) Cell culture; Activity Assays.
RPA120Ca01 Recombinant Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
EPA120Ca61 Eukaryotic Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
PAA120Ca01 Polyclonal Antibody to Stem Cell Factor (SCF) WB; IHC; ICC; IP.
MAA120Ca21 Monoclonal Antibody to Stem Cell Factor (SCF) WB; IHC; ICC; IP.
SEA120Ca ELISA Kit for Stem Cell Factor (SCF) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA120Ca Multiplex Assay Kit for Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.