Multiplex Assay Kit for Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay)

ETGF; TGF-A; Protransforming Growth Factor alpha; EGF-Like TGF

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-97 80
EDTA plasma(n=5) 94-103 101
heparin plasma(n=5) 79-93 82

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-102% 92-101% 98-105% 96-104%
EDTA plasma(n=5) 91-99% 80-91% 83-90% 80-103%
heparin plasma(n=5) 99-105% 90-101% 81-96% 83-92%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TGFa) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Physiology and Biochemistry Protective effects of curcumin, α-lipoic acid, and N-acetylcysteine against carbon tetrachloride-induced liver fibrosis in rats SpringerLink: h875w73171w2147w
Oncology Reports A bone-seeking clone exhibits different biological properties from the ACHN parental human renal cell carcinoma in vivo and in vitro PubMed: PMC3583590
Sci Total Environ. The effects of particulate matter on inflammation of respiratory system: Differences betweenmale and female. pubmed:28174048
International Journal of Biological Sciences CD9 regulates keratinocyte migration by negatively modulating the sheddase activity of ADAM17
JOURNAL OF CELLULAR AND MOLECULAR MEDICINE Polarization of ADAM17‐driven EGFR signalling in electric field‐guided collective migration of epidermal sheets Pubmed: 33164313
Toll-like receptor 5-mediated signaling enhances liver regeneration in mice
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA123Mu02 Recombinant Transforming Growth Factor Alpha (TGFa) Positive Control; Immunogen; SDS-PAGE; WB.
RPA123Mu01 Recombinant Transforming Growth Factor Alpha (TGFa) Positive Control; Immunogen; SDS-PAGE; WB.
PAA123Mu01 Polyclonal Antibody to Transforming Growth Factor Alpha (TGFa) WB; IHC; ICC; IP.
PAA123Mu02 Polyclonal Antibody to Transforming Growth Factor Alpha (TGFa) WB; IHC; ICC; IP.
SEA123Mu ELISA Kit for Transforming Growth Factor Alpha (TGFa) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA123Mu Mini Samples ELISA Kit for Transforming Growth Factor Alpha (TGFa) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA123Mu Multiplex Assay Kit for Transforming Growth Factor Alpha (TGFa) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.