Multiplex Assay Kit for TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay)
CD202b; CD202-B; TEK; VMCM1; Tyrosine Kinase With Immunoglobulin Like And EGF Like Domains 2; Venous Malformations Multiple Cutaneous And Mucosal
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA126Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 348
US$ 362
US$ 382
US$ 409
US$ 436
US$ 476
US$ 536
Result
For more details, please contact local distributors! US$ 670 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-91 | 87 |
EDTA plasma(n=5) | 81-99 | 84 |
heparin plasma(n=5) | 88-103 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 94-103% | 80-101% | 78-102% | 89-103% |
EDTA plasma(n=5) | 80-96% | 93-105% | 90-99% | 94-102% |
heparin plasma(n=5) | 82-92% | 78-89% | 83-91% | 98-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:Tie2) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Anesthesiology | Vasculotide, an angiopoietin-1 mimetic, restores microcirculatory perfusion and microvascular leakage and decreases fluid resuscitation requirements in … Pubmed:28968277 |
British Journal of Anaesthesia | Vasculotide, an angiopoietin-1 mimetic, reduces pulmonary vascular leakage and preserves microcirculatory perfusion during cardiopulmonary bypass in rats 10.1016:j.bja.2018.05.049 |
Intensive Care Med Exp | The effect of targeting Tie2 on hemorrhagic shock-induced renal perfusion disturbances in rats 33997943 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA126Mu02 | Recombinant TEK Tyrosine Kinase, Endothelial (Tie2) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA126Mu01 | Recombinant TEK Tyrosine Kinase, Endothelial (Tie2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA126Mu02 | Polyclonal Antibody to TEK Tyrosine Kinase, Endothelial (Tie2) | WB; IHC; ICC; IP. |
PAA126Mu01 | Polyclonal Antibody to TEK Tyrosine Kinase, Endothelial (Tie2) | WB; IHC; ICC; IP. |
SEA126Mu | ELISA Kit for TEK Tyrosine Kinase, Endothelial (Tie2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA126Mu | Multiplex Assay Kit for TEK Tyrosine Kinase, Endothelial (Tie2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |