Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay)
aHSG; HSGa; A2HS; AHS; FETUA; HSG-A2; Fetuin-A; Alpha 2-HS Glycoprotein; Fetuin A; Alpha-2-Z-Globulin; Ba-alpha-2-Glycoprotein
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA178Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.39-400ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.13 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 472
US$ 490
US$ 517
US$ 553
US$ 590
US$ 644
US$ 726
Result
For more details, please contact local distributors! US$ 907 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-91 | 87 |
EDTA plasma(n=5) | 78-99 | 90 |
heparin plasma(n=5) | 91-98 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alpha-2-Heremans Schmid Glycoprotein (AHSG) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-105% | 79-89% | 96-105% | 95-104% |
EDTA plasma(n=5) | 91-101% | 99-105% | 93-101% | 82-95% |
heparin plasma(n=5) | 87-104% | 94-101% | 85-92% | 84-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:AHSG) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Journal of Proteomics | Proteomic analysis reveals oxidative stress response as the main adaptative physiological mechanism in cows under different production systems ScienceDirect: S1874391912002084 |
Journal of Physiology and Biochemistry | Curcumin prevents liver fat accumulation and serum fetuin-A increase in rats fed a high-fat diet PubMed: 23430567 |
BioMed Research International | Serum Fetuin-A Levels Related with Microalbuminuria in Diet-Induced Obese Rats PubMed: PMC3591142 |
Osteoporosis International | Estrogen increases the transcription of human α2-Heremans-Schmid-glycoprotein by an interplay of estrogen receptor α and activator protein-1. Pubmed: 24504099 |
BMC Pharmacology and Toxicology | A novel 11β-hydroxysteroid dehydrogenase type1 inhibitor CNX-010-49 improves hyperglycemia, lipid profile and reduces body weight in diet induced obese C57B6/J mice with a potential to provide cardio protective benefits Pubmed:25098735 |
Acta Dermatovenerologica Croatica | Relationship Between Serum Fetuin-A Levels and Carotid Intima-media Thickness in Turkish Patients with Mild to Moderate Psoriasis. A Case-control Study PubMed: 26476900 |
Mol Cell Endocrinol | Fetuin A promotes lipotoxicity in β cells through the TLR4 signaling pathway and the role of pioglitazone in anti-lipotoxicity. PubMed: 25986658 |
Ann Dermatol | Evaluation of Arterial Stiffness in Patients with Beh PubMed: 26719639 |
Endocrine | Visceral and subcutaneous adipose tissue express and secrete functional alpha2hsglycoprotein (fetuin a) especially in obesity pubmed:27738888 |
Diabetes Care | Targeted Microbiome Intervention by Microencapsulated Delayed-Release Niacin Beneficially Affects Insulin Sensitivity in Humans pubmed:29212824 |
JOURNAL OF ALZHEIMERS DISEASE | Acute Anti-Inflammatory Markers ITIH4 and AHSG in Mice Brain of a Novel Alzheimer's Disease Model Pubmed: 30958362 |
Journal of Alzheimer's Disease | A New Serum Biomarker Set to Detect Mild Cognitive Impairment and Alzheimer's Disease by Peptidome Technology Pubmed: 31771070 |
Sci Rep | Ileal transposition helps to regulate plasma hepatokine levels in obese Zucker (Crl: ZUC (ORL)-Lepr fa) rats 33833309 |
J Obstet Gynaecol Res | Predıctıve value of pregnancy of follıcular fluıd fetuın‐A and‐B levels ın infertıle women after intra‐cytoplasmic sperm injection 34708901 |