Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay)
Glycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA190Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypePlasma and erythrocyte lysates
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 405
US$ 420
US$ 443
US$ 475
US$ 506
US$ 552
US$ 622
Result
For more details, please contact local distributors! US$ 778 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-101 | 88 |
EDTA plasma(n=5) | 88-95 | 91 |
heparin plasma(n=5) | 84-105 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-92% | 92-99% | 78-104% | 95-105% |
EDTA plasma(n=5) | 93-101% | 84-98% | 84-98% | 87-96% |
heparin plasma(n=5) | 83-92% | 96-103% | 95-105% | 91-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:HbA1c) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
J Am Coll Nutr | The Effect of Vitamin D Supplementation on Glycemic Control and Lipid Profile in Patients with Type 2 Diabetes Mellitus PubMed: 26391639 |
Journal of the American College of Nutrition | The Effect of Vitamin D Supplementation on Glycemic Control and Lipid Profile in Patients with Type 2 Diabetes Mellitus. pubmed:26391639 |
Journal of Endocrinology and Metabolism | Circulating Betatrophin and Hepatocyte Growth Factor in Type 2 Diabetic Patients: Their Relationship With Disease Prognosis 405 |
Molecular nutrition & food research | Chicory inulin ameliorates type 2 diabetes mellitus and suppresses JNK and MAPK pathways in vivo and in vitro pubmed:28105758 |
33 | d-Ribose as a Contributor to Glycated Haemoglobin pubmed:29033370 |
Journal of Functional Foods | Hypoglycemic effect of Hypericum attenuatum Choisy extracts on type 2 diabetes by regulating glucolipid metabolism and modulating gut microbiota |
West Indian Medical Journal | Plasma Cellular Hypoxia, Mitochondrial Dysfunction, Disease Risk and Prognostic Factors in Type 2 Diabetic Patients in Saudi Arabia. |
Journal of Occupational and Environmental Hygiene | Stressors, allostatic load, and health outcomes among women hotel housekeepers: A pilot study Pubmed: 30615593 |
Cell Reports | Parabacteroides distasonis Alleviates Obesity and Metabolic Dysfunctions via Production of Succinate and Secondary Bile Acids Pubmed: 30605678 |
Journal of Agricultural and Food Chemistry | Gymnemic acid alleviates type 2 diabetes mellitus and suppresses endoplasmic reticulum stress in vivo and in vitro |
Journal of Clinical Medicine | 1H Nuclear Magnetic Resonance (NMR)-Based Cerebrospinal Fluid and Plasma Metabolomic Analysis in Type 2 Diabetic Patients and Risk Prediction for Diabetic … Pubmed: 31248127 |
Food & Function | Gymnemic Acid Alleviates Inflammation and Insulin Resistance via PPARδ-and NFκB-mediated pathways in db/db mice. |
Obesity Surgery | Duodenal-Jejunal Bypass Ameliorates Type 2 Diabetes Mellitus by Activating Insulin Signaling and Improving Glucose Utilization in the Brain Pubmed: 31605365 |
Acta Diabetologica | Modulation of gut microbiota contributes to effects of intensive insulin therapy on intestinal morphological alteration in high-fat-diet-treated mice Pubmed: 31749050 |
Open Access Macedonian Journal of Medical Sciences | Inhibition of Receptor for Advanced Glycation End Products as New Promising Strategy Treatment in Diabetic Retinopathy Pubmed: 32165929 |
Cell Reports | Activation of a Specific Gut Bacteroides-Folate-Liver Axis Benefits for the Alleviation of Nonalcoholic Hepatic Steatosis Pubmed: 32783933 |
The effects of different intensity endurance and resistance exercise on diabetic-related blood profiles in impaired glucose tolerance mice | |
Revista Internacional de Andrologia | Relation of pharmacopenile duplex ultrasonography parameters and glycated hemoglobin (HbA1c) in diabetic patients with erectile dysfunction 33334711 |
Advanced Theory and Simulations? | Identification of Key Contributive Compounds in a Herbal Medicine: A Novel Mathematic¡ªBiological Evaluation Approach |
Dis Markers | The Roles of Liver Inflammation and the Insulin Signaling Pathway in PM2. 5 Instillation-Induced Insulin Resistance in Wistar Rats 34745386 |
Antioxidants | Antioxidant Effect of Tyr-Ala Extracted from Zein on INS-1 Cells and Type 2 Diabetes High-Fat-Diet-Induced Mice Pubmed:35740008 |
P001–Inv. Clínica |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
NPA190Mu01 | Native Glycated Hemoglobin A1c (HbA1c) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA190Mu01 | Polyclonal Antibody to Glycated Hemoglobin A1c (HbA1c) | WB; IHC; ICC; IP. |
WEA190Mu | Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA190Mu | ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA190Mu | Mini Samples ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA190Mu | Multiplex Assay Kit for Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA190Mu11 | ELISA Kit DIY Materials for Glycated Hemoglobin A1c (HbA1c) | Main materials for "Do It (ELISA Kit) Yourself". |