- Product No.LMA207Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.1-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.033 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 472
US$ 490
US$ 517
US$ 553
US$ 590
US$ 644
US$ 726
Result
For more details, please contact local distributors! US$ 907 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 92-99 | 96 |
EDTA plasma(n=5) | 97-104 | 101 |
heparin plasma(n=5) | 94-105 | 101 |
sodium citrate plasma(n=5) | 80-101 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-101% | 85-94% | 92-99% | 92-99% |
EDTA plasma(n=5) | 80-101% | 78-92% | 92-99% | 80-105% |
heparin plasma(n=5) | 87-101% | 95-105% | 78-104% | 83-94% |
sodium citrate plasma(n=5) | 91-102% | 90-103% | 88-96% | 79-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:ALT) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Cancer Gene Therapy | Enhanced antitumor activity by combining an adenovirus harboring ING4 with cisplatin for hepatocarcinoma cells Nature: 201067 |
Endocrinology. | Additive effects of nicotine and high-fat diet on hepatic steatosis in male mice. PubMed: 23093702 |
Kidney International | Adrenocorticotropic hormone ameliorates acute kidney injury by steroidogenic-dependent and -independent mechanisms PubMed: PMC3612362 |
Proceedings of the National Academy of Sciences | Pathogenesis of emerging severe fever with thrombocytopenia syndrome virus in C57/BL6 mouse model PubMed: PMC3382536 |
African Journal of Pharmacy and Pharmacology | Protective effect of Panax ginseng against N-acetyl-p-aminophenol-induced hepatotoxicity in rats Academicjournals: Source |
Kidney International | Adrenocorticotropic hormone ameliorates acute kidney injury by steroidogenic-dependent and-independent mechanisms Pubmed: 23325074 |
European Journal of Pharmacology | Protective effect of Et-1 receptor antagonist bosentan on paracetamol induced acute liver toxicity in rats ScienceDirect: S0014299914000235 |
Eur J Nutr. | Bifidobacterium pseudocatenulatum CECT7765 promotes a TLR2-dependent anti-inflammatory response in intestinal lymphocytes from mice with cirrhosis Pubmed:25657013 |
Experimental and Molecular Pathology | Resolvin E1 and chemerin C15 peptide do not improve rodent non-alcoholic steatohepatitis Pubmed:25681756 |
Gastroenterol Res Pract | Assessing the Effect of Leptin on Liver Damage in Case of Hepatic Injury Associated with Paracetamol Poisoning PubMed: 26697061 |
FNG & Bilim Tıp Dergisi | The effects of subacute deltamethrin exposure on rat liver: histochemical, immunohistochemical, and biochemical study xmlui:11446 |
Gastroenterol Res Pract. | Advanced Studies in Clinical and Experimental Research in Gastroenterology Pubmed:26955389 |
DARU Journal of Pharmaceutical Sciences | Effects of developmental exposure to silver in ionic and nanoparticle form: A study in rats pubmed:27716437 |
Oncotarget | Dihydromyricetin protects against liver ischemia/reperfusion induced apoptosis via activation ofFOXO3a-mediated autophagy. pubmed:27793014 |
Scientific Reports | Adiponectin protects the rats liver against chronic intermittent hypoxia induced injury throughAMP-activated protein kinase pathway. pubmed:27678302 |
Biochimica et Biophysica Acta (BBA)-General Subjects | Modulation of gut microbiota contributes to curcumin-mediated attenuation of hepatic steatosis in rats pubmed:28341485 |
Gastroenterology Research and Practice | Antifibrotic Effect of Lactulose on a Methotrexate-Induced Liver Injury Model pubmed:28912805 |
PLoS Pathogens | Alcohol-associated intestinal dysbiosis impairs pulmonary host defense against Klebsiella pneumoniae. pubmed:28604843 |
FEBS Open Bio | A critical role of hepatitis B virus polymerase in cirrhosis, hepatocellular carcinoma, and steatosis Pubmed:29321963 |
Rolle von CMKLR1 und dessen Liganden bei der nicht-alkoholischen Fettlebererkrankung Regensburg:Source | |
Cumhuriyet Medical Journal | The valuable effects of potent antioxidant curcumin in cisplatin induced liver and kidney injury DOI:Source |
BMC Complementary and Alternative Medicine | Hepatoprotective activity of Erythrina× neillii leaf extract and characterization of its phytoconstituents Pubmed: 28095910 |
Scientific Reports | Brg1 promotes liver regeneration after partial hepatectomy via regulation of cell cycle Pubmed: 30787318 |
Brain Behavior and Immunity | Corticosterone-mediated microglia activation affects dendritic spine plasticity and motor learning functions in minimal hepatic encephalopathy Pubmed: 31437533 |
Biomed Research International | Liraglutide Attenuates Nonalcoholic Fatty Liver Disease by Modulating Gut Microbiota in Rats Administered a High-Fat Diet Pubmed: 32149099 |
Frontiers in Immunology | CD47 Deficiency in Mice Exacerbates Chronic Fatty Diet-Induced Steatohepatitis Through Its Role in Regulating Hepatic Inflammation and Lipid Metabolism Pubmed: 32158445 |
Nanomaterials | Biological Safety and Biodistribution of Chitosan Nanoparticles Pubmed: 32340313 |
European Journal of Biology | Effects of Tempol in Lipopolysaccharide-Induced Liver Injury |
Pathogens | Antimalarial Effect of the Total Glycosides of the Medicinal Plant, Ranunculus japonicus 33925018 |
Gastroenterol Res Pract | An Experimental Study: Benefits of Digoxin on Hepatotoxicity Induced by Methotrexate Treatment 34804155 |
Int Immunopharmacol | Taraxasterol mitigates Con A-induced hepatitis in mice by suppressing interleukin-2 expression and its signaling in T lymphocytes 34848154 |
J Magn Reson Imaging | Water Specific MRI T1 Mapping for Evaluating Liver Inflammation Activity Grades in Rats With Methionine‐Choline‐Deficient Diet‐Induced Nonalcoholic Fatty Liver … Pubmed:35212074 |
Medcomm | Blockade of mIL‐6R alleviated lipopolysaccharide‐induced systemic inflammatory response syndrome by suppressing NF‐κB‐mediated Ccl2 expression and … Pubmed:35548710 |
International Immunopharmacology | Dimethyl fumarate ameliorates autoimmune hepatitis in mice by blocking NLRP3 inflammasome activation Pubmed:35605433 |
Catalog No. | Related products for research use of Bos taurus; Bovine (Cattle) Organism species | Applications (RESEARCH USE ONLY!) |
RPA207Bo01 | Recombinant Alanine Aminotransferase (ALT) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA207Bo01 | Polyclonal Antibody to Alanine Aminotransferase (ALT) | WB; IHC; ICC; IP. |
MAA207Bo21 | Monoclonal Antibody to Alanine Aminotransferase (ALT) | WB; IHC; ICC; IP. |
SEA207Bo | ELISA Kit for Alanine Aminotransferase (ALT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA207Bo | Multiplex Assay Kit for Alanine Aminotransferase (ALT) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |