Multiplex Assay Kit for Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay)
SPO; Salivary peroxidase
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA296Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- Sample TypeMilk, tear and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 472
US$ 490
US$ 517
US$ 553
US$ 590
US$ 644
US$ 726
Result
For more details, please contact local distributors! US$ 907 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 83-91 | 88 |
EDTA plasma(n=5) | 94-103 | 99 |
heparin plasma(n=5) | 96-105 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 82-101% | 88-95% | 83-99% | 86-101% |
EDTA plasma(n=5) | 83-97% | 85-92% | 79-97% | 86-95% |
heparin plasma(n=5) | 78-91% | 87-105% | 98-105% | 98-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:LPO) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Med Sci Monit.? | The assessment of sIgA, histatin-5, and lactoperoxidase levels in saliva of adolescents with dental caries Pubmed:Pmc4087079 |
Journal of clinical periodontology | Association of salivary peroxidase activity and concentration with periodontal health–a validity study pubmed:28555944 |
Oncology Letters | Mechanism of anticancer action of novel berenil complex of platinum (II) combined with anti-MUC1 in MCF-7 breast cancer cells Pubmed:29434943 |
Validitätsstudie zur Assoziation von Speichelperoxidase-Aktivität und-Konzentration mit der parodontalen Gesundheit | |
BRAIN RESEARCH | Cerebrospinal fluid lactoperoxidase level is enhanced in idiopathic Parkinson's disease, and correlates with levodopa equivalent daily dose 33676939 |
Catalog No. | Related products for research use of Bos taurus; Bovine (Cattle) Organism species | Applications (RESEARCH USE ONLY!) |
RPA296Bo01 | Recombinant Lactoperoxidase (LPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA296Bo01 | Polyclonal Antibody to Lactoperoxidase (LPO) | WB; IHC; ICC; IP. |
MAA296Bo21 | Monoclonal Antibody to Lactoperoxidase (LPO) | WB; IHC; ICC; IP. |
SEA296Bo | ELISA Kit for Lactoperoxidase (LPO) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA296Bo | CLIA Kit for Lactoperoxidase (LPO) | Chemiluminescent immunoassay for Antigen Detection. |
LMA296Bo | Multiplex Assay Kit for Lactoperoxidase (LPO) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |