Multiplex Assay Kit for Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay)

T49; PT49; Fibroleukin

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-99 94
EDTA plasma(n=5) 96-104 101
heparin plasma(n=5) 97-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 92-105% 89-104% 78-96%
EDTA plasma(n=5) 98-105% 87-94% 85-93% 95-105%
heparin plasma(n=5) 78-92% 96-104% 81-103% 91-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:FGL2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Gut. Expression of B and T lymphocyte attenuator (BTLA) in macrophages contributes to the fulminant hepatitis caused by murine hepatitis virus strain-3 PubMed: 22637698
Hepatogastroenterology. Plasma fibrinogen-like protein 2 levels in patients with non-alcoholic fatty liver disease. PubMed: 22024080
PLoS Pathogens Programmed Death (PD)-1-Deficient Mice Are Extremely Sensitive to Murine Hepatitis Virus Strain-3 (MHV-3) Infection PubMed: PMC3131267
Immunology letters Tumor necrosis factor α (TNF-α) receptor-I is required for TNF-α-mediated fulminant virus hepatitis caused by murine hepatitis virus strain-3 infection. Pubmed: 24286726
Immunol Lett. Tumor necrosis factor α (TNF-α) receptor-I is required for TNF-α-mediated fulminant virus hepatitis caused by murine hepatitis virus strain-3 infection Pubmed:24286726
NATURE COMMUNICATIONS VSIG4 inhibits proinflammatory macrophage activation by reprogramming mitochondrial pyruvate metabolism pubmed:29109438
Cancer Medicine Soluble fibrinogen‐like protein 2 ameliorates acute rejection of liver transplantation in rat via inducing Kupffer cells M2 polarization Pubmed:29749104
BMC Infectious Diseases Soluble fibrinogen-like protein 2 levels in patients with hepatitis B virus-related liver diseases Pubmed: 30419833
Int J Gynaecol Obstet Tandem mass tag©\based quantitative proteomic profiling of the serum of patients with abnormal uterine bleeding associated with copper intrauterine device 33354778
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA512Ra01 Recombinant Fibrinogen Like Protein 2 (FGL2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA512Ra01 Polyclonal Antibody to Fibrinogen Like Protein 2 (FGL2) WB; IHC; ICC; IP.
MAA512Ra21 Monoclonal Antibody to Fibrinogen Like Protein 2 (FGL2) WB; IHC; ICC; IP.
SEA512Ra ELISA Kit for Fibrinogen Like Protein 2 (FGL2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA512Ra Multiplex Assay Kit for Fibrinogen Like Protein 2 (FGL2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.