Multiplex Assay Kit for Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD142; FIII; F3; TFA; Thromboplastin; Coagulation Factor III

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
EDTA plasma(n=5) 78-94 88
heparin plasma(n=5) 97-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
EDTA plasma(n=5) 87-99% 78-103% 82-103% 95-105%
heparin plasma(n=5) 79-104% 95-103% 96-103% 89-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TF) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Peptides Calcitonin gene-related peptide-mediated antihypertensive and anti-platelet effects by rutaecarpine in spontaneously hypertensive rats PubMed: 18625276
Canadian Journal of Physiology and Pharmacology Increased plasma level of asymmetric dimethylarginine in hypertensive rats facilitates platelet aggregation: role of plasma tissue factor Nrcresearchpress: y10-115
International immunopharmacology Ruscogenin attenuates monocrotaline-induced pulmonary hypertension in rats Pubmed: 23538027
BioMed research international Endothelial gene expression and molecular changes in response to radiosurgery in in vitro and in vivo models of cerebral arteriovenous malformations Pubmed: 24199192
The Journal of Biological Chemistry Sphingolipid Pathway Regulates Innate Immune Responses at the Fetomaternal Interface during Pregnancy Pubmed:25505239
Hippokratia Thrombosis in Hemodialysis Patients; Their Association with Tissue Factor and Tissue Factor Pathway Inhibitor PubMed: 20011089
shock Noble-Collip Drum Trauma Induces Disseminated Intravascular Coagulation But Not Acute Coagulopathy of Trauma-Shock PubMed: 25423126
Perfusion Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing PubMed: 26243277
Molecular Nutrition & Food Research Trans‐fatty acid promotes thrombus formation in mice by aggravating antithrombogenic endothelial functions via Toll‐like receptors PubMed: 25546502
Food Funct The effects of polysaccharides from the root of Angelica sinensis on tumor growth and iron metabolism in H22-bearing mice Pubmed:26757699
Blood Cells, Inflammation and Infection Nebulized Heparin Attenuates Pulmonary Coagulopathy and Inflammation through Alveolar Macrophages in a Rat Model of Acute Lung Injury pubmed:29202212
Thrombosis andHaemostasis Nebulized anti-coagulants as a therapy for acute lung injury and acute respiratory distress syndrome Pubmed: 29202212
Journal of Thrombosis and Haemostasis Effects of nebulized antithrombin and heparin on inflammatory and coagulation alterations in an acute lung injury model in rats Pubmed: 31755229
Mediators Inflamm Amelioration of Coagulation Disorders and Inflammation by Hydrogen-Rich Solution Reduces Intestinal Ischemia/Reperfusion Injury in Rats through NF-κB … Pubmed: 32587471
International Journal of Clinical Practice Effect of Glucocorticoid Administration in Intravenous Pulses on Selected Parameters of the Coagulation System Pubmed:35685509
Catalog No. Related products for research use of Sus scrofa; Porcine (Pig) Organism species Applications (RESEARCH USE ONLY!)
RPA524Po01 Recombinant Tissue Factor (TF) Positive Control; Immunogen; SDS-PAGE; WB.
PAA524Po01 Polyclonal Antibody to Tissue Factor (TF) WB; IHC; ICC; IP.
MAA524Po21 Monoclonal Antibody to Tissue Factor (TF) WB; IHC; ICC; IP.
SEA524Po ELISA Kit for Tissue Factor (TF) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA524Po Multiplex Assay Kit for Tissue Factor (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.