Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay)
SERPINE1; PLANH1; Serpin Peptidase Inhibitor Clade E Member 1; Nexin,Plasminogen Activator Inhibitor Type 1 Serpin E1; Endothelial plasminogen activator inhibitor
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA532Si
- Organism SpeciesRhesus monkey (Simian) Same name, Different species.
- Sample TypePlasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.78-800pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.26 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 505
US$ 525
US$ 554
US$ 593
US$ 632
US$ 690
US$ 778
Result
For more details, please contact local distributors! US$ 972 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-99 | 90 |
EDTA plasma(n=5) | 84-101 | 92 |
heparin plasma(n=5) | 81-101 | 87 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-97% | 88-102% | 86-95% | 95-103% |
EDTA plasma(n=5) | 86-95% | 97-105% | 78-101% | 90-98% |
heparin plasma(n=5) | 88-95% | 93-101% | 95-103% | 97-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PAI1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Breast Cancer Research and Treatment | Oral administration of benzyl-isothiocyanate inhibits solid tumor growth and lung metastasis of 4T1 murine mammary carcinoma cells in BALB/c mice SpringerLink: f3w831267267p277 |
Clin Appl Thromb Hemost. | Is There Any Association Between Thrombosis and Tissue Factor Pathway Inhibitor Levels in Patients With Vitamin D Deficiency? Pubmed: 24203351 |
Molecular Nutrition & Food Research | Trans‐fatty acid promotes thrombus formation in mice by aggravating antithrombogenic endothelial functions via Toll‐like receptors PubMed: 25546502 |
Archives of Physiology and Biochemistry | Activation of cardiac renin–angiotensin system and plasminogen activator inhibitor-1 gene expressions in oral contraceptive-induced cardiometabolic disorder Pubmed:26934364 |
Naunyn-Schmiedeberg's Archives of Pharmacology | Combined oral contraceptive-induced hypertension is accompanied by endothelial dysfunction and upregulated intrarenal angiotensin II type 1 receptor gene expression pubmed:27447455 |
Environmental toxicology and pharmacology | Combined oral contraceptive and nitric oxide synthesis inhibition synergistically causes cardiac hypertrophy and exacerbates insulin resistance in female rats. pubmed:28376377 |
Annals of Clinical & Laboratory Science | Alteration of Hemostatic Parameters in Patients with Different Levels of Subclinical Hypothyroidism and the Effect of L-thyroxine Treatment pubmed:28249913 |
Pharmacological reports | Anti-inflammatory and antithrombotic effects of nicotine exposure in oral contraceptive-induced insulin resistance are glucocorticoid-independent pubmed:28349880 |
Haematologica | Cytoprotective and pro-angiogenic functions of thrombomodulin are preserved in the C loop of the fifth epidermal growth factor-like domain Pubmed:29903766 |
Biomedicine & Pharmacotherapy | Puerarin prevents vascular endothelial injury through suppression of NF-κB activation in LPS-challenged human umbilical vein endothelial cells Pubmed:29775893 |
Archives of Physical Medicine and Rehabilitation | Impact of Regular Physical Activity on Adipocytokines and Cardiovascular Characteristics in Spinal Cord–Injured Subjects Pubmed:29548578 |
Marine Drugs | Anticoagulant and Antithrombotic Properties in Vitro and in Vivo of a Novel Sulfated Polysaccharide from Marine Green Alga Monostroma nitidum Pubmed: 31027312 |
Experimental and Therapeutic Medicine | IKKβ regulates the expression of coagulation and fibrinolysis factors through the NF‑κB canonical pathway in LPS‑stimulated alveolar epithelial cells type II Pubmed: 31572531 |
Phytomedicine | Sodium aescinate significantly suppress postoperative peritoneal adhesion by inhibiting the RhoA/ROCK signaling pathway Pubmed: 32120245 |
Sci Rep | Fibroblast growth factor-21 as a novel metabolic factor for regulating thrombotic homeostasis Pubmed:35013379 |
Phytomedicine | Multi-omics analysis reveals the mechanisms of action and therapeutic regimens of traditional Chinese medicine, Bufei Jianpi granules: Implication for COPD drug … Pubmed:35121390 |
Catalog No. | Related products for research use of Rhesus monkey (Simian) Organism species | Applications (RESEARCH USE ONLY!) |
RPA532Si01 | Recombinant Plasminogen Activator Inhibitor 1 (PAI1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA532Si01 | Polyclonal Antibody to Plasminogen Activator Inhibitor 1 (PAI1) | WB; IHC; ICC; IP. |
MAA532Si21 | Monoclonal Antibody to Plasminogen Activator Inhibitor 1 (PAI1) | WB; IHC; ICC; IP. |
SEA532Si | ELISA Kit for Plasminogen Activator Inhibitor 1 (PAI1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA532Si | Multiplex Assay Kit for Plasminogen Activator Inhibitor 1 (PAI1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |