Multiplex Assay Kit for Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay)
c-GMP; 3',5'-Cyclic GMP; Cyclic 3',5'-GMP; Guanosine 3',5'-Cyclic Phosphate
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA577Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range9.77-10000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 3.257 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 497
US$ 516
US$ 544
US$ 583
US$ 621
US$ 678
US$ 764
Result
For more details, please contact local distributors! US$ 955 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 87-103 | 99 |
EDTA plasma(n=5) | 80-91 | 83 |
heparin plasma(n=5) | 78-89 | 81 |
sodium citrate plasma(n=5) | 84-105 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-103% | 86-93% | 94-102% | 79-102% |
EDTA plasma(n=5) | 96-103% | 80-94% | 82-95% | 85-101% |
heparin plasma(n=5) | 99-105% | 93-105% | 80-92% | 89-101% |
sodium citrate plasma(n=5) | 80-92% | 95-102% | 95-104% | 91-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:cGMP) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Life Sci | Cardioprotective effects of baicalein on heart failure via modulation of Ca2 PubMed: 26706290 |
Life Sci | Cardioprotective effects of baicalein on heart failure via modulation of Ca(2+) handling proteins in vivo and in vitro Pubmed:26706290 |
Taylor & Francis | Influences of Hyriopsis cumingii polysaccharides on mice immunosignaling molecules and T lymphocyte differentiation 09540105.2017.1306494 |
Biochemical and Biophysical Research Communications | Probucol improves erectile function via Activation of Nrf2 and coordinates the HO-1/DDAH/PPAR-γ/eNOS pathways in streptozotocin-induced diabetic rats Pubmed: 30454888 |
International Journal of Peptide Research and Therapeutics | ANP/NPRA Inhibits Epithelial-Mesenchymal Transition of Airway by Targeting Smad3 in Asthma |
Evidence-Based Complementary and Alternative Medicine | iTRAQ-Based Proteomics to Reveal the Mechanism of Hypothalamus in Kidney-Yin Deficiency Rats Induced by Levothyroxine |
Experimental Lung Research | Atrial natriuretic peptide inhibits epithelial-mesenchymal transition (EMT) of bronchial epithelial cells through cGMP/PKG signaling by targeting Smad3 in a murine … Pubmed: 31496319 |
Neuroscience Letters | Effect of cGMP-activated aquaporin 1 on TRPV4 in rats with allodynia induced by chronic compression of the dorsal root ganglion Pubmed: 31790718 |
Aging Male | Effect of tadalafil on penile nitric oxide synthase and corporal smooth muscle in rats under dutasteride treatment Pubmed: 32160825 |
Biomaterials | Epigallocatechin gallate mediated sandwich-like coating for mimicking endothelium with sustained therapeutic nitric oxide generation and heparin release Pubmed: 33143876 |
Biomed Pharmacother | Antihypertensive effects of allicin on spontaneously hypertensive rats via vasorelaxation and hydrogen sulfide mechanisms Pubmed: 32480217 |
Pflügers Archiv : European journal of physiology | The role of adrenergic and muscarinic receptors in stress-induced cardiac injury 34245378 |
Biomaterials | A nitric oxide-eluting and REDV peptide-conjugated coating promotes vascular healing Pubmed:35366606 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CEA577Ge | ELISA Kit for Cyclic Guanosine Monophosphate (cGMP) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA577Ge | Mini Samples ELISA Kit for Cyclic Guanosine Monophosphate (cGMP) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA577Ge | Multiplex Assay Kit for Cyclic Guanosine Monophosphate (cGMP) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |