Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay)
Hypocretin-1
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA607Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 393
US$ 408
US$ 431
US$ 461
US$ 491
US$ 537
US$ 605
Result
For more details, please contact local distributors! US$ 756 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-104 | 101 |
EDTA plasma(n=5) | 92-101 | 96 |
heparin plasma(n=5) | 90-99 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-91% | 84-103% | 78-101% | 87-101% |
EDTA plasma(n=5) | 78-93% | 93-101% | 94-102% | 79-97% |
heparin plasma(n=5) | 78-97% | 78-97% | 91-105% | 93-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:OXA) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Frontiers in Neurology | Neuro-Glial and Systemic Mechanisms of Pathological Responses in Rat Models of Primary Blast Overpressure Compared to “Composite” Blast PubMed: PMC3275793 |
Neurological Sciences | Pentylenetetrazol-induced seizures are exacerbated by sleep deprivation through orexin receptor-mediated hippocampal cell proliferation Pubmed: 23852314 |
Peptides | Orexin-A-induced ERK1/2 activation reverses impaired spatial learning and memory in pentylenetetrazol-kindled rats via OX1R-mediated hippocampal neurogenesis. Pubmed: 24321199 |
Alcohol Alcohol | Orexin in Patients with Alcohol Dependence Treated for Relapse Prevention: A Pilot Study PubMed: 26597795 |
Indian Journal of Medical Research and Pharmaceutical Sciences | Evaluation of Antidiabetic And Insulintropic Potential of Nigella Sativa Seeds Water Extract and /or Alpha Lipoic Acid in Type 2 Diabetic Rats Issues%20Pdf: Vol.2 |
J Clin Res Pediatr Endocninol | Correlation of Brain Neuropeptide (Nesfatin-1 and Orexin-A) Concentrations with Anthropometric and Biochemical Parameters in Malnourished Children PubMed: 26831553 |
Neural Regen Res | Resuscitation therapy for traumatic brain injury-induced coma in rats: mechanisms of median nerve electrical stimulation PubMed: 26170820 |
Mol Med Rep | Wake-promoting actions of median nerve stimulation in TBI-induced coma: An investigation of orexin-A and orexin receptor 1 in the hypothalamic region PubMed: 26059340 |
Mol Neurobiol | Application of the Co-culture Membrane System Pointed to a Protective Role of Catestatin on Hippocampal Plus Hypothalamic Neurons Exposed to Oxygen and Glucose Deprivation article:10.1007 |
Neural Regeneration Research | Wake-promoting effects of vagus nerve stimulation after traumatic brain injury: upregulation of orexin-A and orexin receptor type 1 expression in the prefrontal … Pubmed:29557373 |
Journal of Translational Medicine | Recurrent circadian fasting (RCF) improves blood pressure, biomarkers of cardiometabolic risk and regulates inflammation in men Pubmed: 31426866 |
iraqi journal of science | Relationship Between Orexin-A and Insulin Resistance in Patients with Type 2 Diabetes Mellitus |
Brain Sci | Changes in the Orexin System in Rats Exhibiting Learned Helplessness Behaviors 34942932 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
CEA607Hu | ELISA Kit for Orexin A (OXA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA607Hu | Multiplex Assay Kit for Orexin A (OXA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |