Multiplex Assay Kit for Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay)

PDGF-BB

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 98
EDTA plasma(n=5) 94-105 101
heparin plasma(n=5) 91-99 96
sodium citrate plasma(n=5) 97-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-97% 98-105% 91-101% 85-103%
EDTA plasma(n=5) 83-94% 85-99% 82-96% 86-94%
heparin plasma(n=5) 94-103% 82-97% 78-95% 88-104%
sodium citrate plasma(n=5) 94-105% 78-104% 98-105% 83-90%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PDGF BB) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Therapeutics and Clinical Risk Management Elevated blood plasma levels of epinephrine, norepinephrine, tyrosine hydroxylase, TGFβ1, and TNFα associated with high-altitude pulmonary edema in an Indian population. pubmed:27540296
PeerJ Platelet-rich concentrate in serum free medium enhances osteogenic differentiation of bone marrow-derived human mesenchymal stromal cells pubmed:27651984
Biosens Bioelectron A biolayer interferometry-based enzyme-linked aptamer sorbent assay for real-time and highly sensitive detection of PDGF-BB pubmed:29125972
Anticancer Research Association Between Endothelial Progenitor Cells and Treatment Response in Non-Squamous Non-small Cell Lung Cancer Treated with Bevacizumab. pubmed:28982871
EBioMedicine Modulating endothelial adhesion and migration impacts stem cell therapies efficacy Pubmed: 32942121
sensors and actuators b-chemical A light-induced self-powered competitive immunosensor for the detection of platelet derived growth factor-BB via an elaborately assembled bioconjugate
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA633Hu01 Recombinant Platelet Derived Growth Factor BB (PDGF BB) Positive Control; Immunogen; SDS-PAGE; WB.
EPA633Hu61 Eukaryotic Platelet Derived Growth Factor BB (PDGF BB) Positive Control; Immunogen; SDS-PAGE; WB.
APA633Hu01 Active Platelet Derived Growth Factor BB (PDGF BB) Cell culture; Activity Assays.
PAA633Hu01 Polyclonal Antibody to Platelet Derived Growth Factor BB (PDGF BB) WB; IHC; ICC; IP.
MAA633Hu21 Monoclonal Antibody to Platelet Derived Growth Factor BB (PDGF BB) WB; IHC; ICC; IP.
SEA633Hu ELISA Kit for Platelet Derived Growth Factor BB (PDGF BB) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA633Hu Multiplex Assay Kit for Platelet Derived Growth Factor BB (PDGF BB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.