Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay)
VGR; VGR1; Vegetal Related Growth Factor(TGFB-Related); VG-1-related protein
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA646Ov
- Organism SpeciesOvis aries; Ovine (Sheep) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 505
US$ 525
US$ 554
US$ 593
US$ 632
US$ 690
US$ 778
Result
For more details, please contact local distributors! US$ 972 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 84-98 | 94 |
EDTA plasma(n=5) | 96-104 | 99 |
heparin plasma(n=5) | 87-101 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-104% | 80-89% | 93-101% | 84-92% |
EDTA plasma(n=5) | 99-105% | 88-96% | 98-105% | 81-93% |
heparin plasma(n=5) | 91-105% | 81-91% | 87-98% | 82-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:BMP6) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
International Journal of Cardiology | Valvular osteoclasts in calcification and aortic valve stenosis severity PubMed: 23452891 |
Polskie Archiwum Medycyny Wewn Trznej | New parameters in iron metabolism and functional iron deficiency in patients on maintenance hemodialysis PubMed: 23111696 |
PLoS ONE | A Combinatorial Relative Mass Value Evaluation of Endogenous Bioactive Proteins in Three-Dimensional Cultured Nucleus Pulposus Cells of Herniated Intervertebral Discs: Identification of Potential Target Proteins for Gene Therapeutic Approaches Plosone: Source |
journal of biomedical materials research part b-applied biomaterials | In vitro chondrogenesis by BMP6 gene therapy Pubmed: 23077084 |
Journal of Clinical Pathology | Association of hepatic oxidative stress and iron dysregulation with HCC development after interferon therapy in chronic hepatitis C PubMed: 26290259 |
Clinical and Experimental Pharmacology and Physiology | Bone morphogenetic protein 6—a possible new player in pathophysiology of heart failure pubmed:27592865 |
International Journal of Biological Macromolecules | SEQUENTIAL IGF-1 AND BMP-6 RELEASING CHITOSAN/ALGINATE/PLGA HYBRID SCAFFOLDS FOR PERIODONTAL REGENERATION pubmed:28601648 |
Elife | The transcriptomic and epigenetic map of vascular quiescence in the continuous lung endothelium Pubmed:29749927 |
Catalog No. | Related products for research use of Ovis aries; Ovine (Sheep) Organism species | Applications (RESEARCH USE ONLY!) |
SEA646Ov | ELISA Kit for Bone Morphogenetic Protein 6 (BMP6) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA646Ov | Multiplex Assay Kit for Bone Morphogenetic Protein 6 (BMP6) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |