Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay)
HPA; HPR1; HPSE1; HSE1; Endo-glucoronidase;
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA711Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 427
US$ 443
US$ 468
US$ 501
US$ 534
US$ 583
US$ 657
Result
For more details, please contact local distributors! US$ 821 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 92-105 | 101 |
EDTA plasma(n=5) | 88-97 | 92 |
heparin plasma(n=5) | 97-105 | 101 |
sodium citrate plasma(n=5) | 85-95 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-101% | 79-93% | 80-95% | 84-91% |
EDTA plasma(n=5) | 78-88% | 89-103% | 80-95% | 98-105% |
heparin plasma(n=5) | 95-104% | 92-101% | 92-101% | 92-101% |
sodium citrate plasma(n=5) | 80-104% | 84-98% | 85-92% | 80-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:HPSE) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Plos one | PG545, a Heparan Sulfate Mimetic, Reduces Heparanase Expression In Vivo, Blocks Spontaneous Metastases and Enhances Overall Survival in the 4T1 Breast Carcinoma Model Plosone: Source |
Journal of Medical Science | Assessment of heparanase and heparin-binding growth and angiogenesis factors in the uterine cavity ? uid in women with impaired reproduction Nowinylekarskie:Source |
Int J Clin Exp Pathol | Unfractionated heparin attenuates intestinal injury in mouse model of sepsis by inhibiting heparanase PubMed: 26191183 |
Tumour Biology | PI-88 inhibits postoperative recurrence of hepatocellular carcinoma via disrupting the surge of heparanase after liver resection PubMed: 26415733 |
Journal of Medical Science | Assessment of heparanase and heparin-binding growth and angiogenesis factors in the uterine cavity fluid in women with impaired reproduction article:84 |
Renal Failure | Plasma heparanase is associated with blood glucose levels but not urinary microalbumin excretion in type 2 diabetic nephropathy at the early stage pubmed:28994624 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA711Ra01 | Recombinant Heparanase (HPSE) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA711Ra01 | Polyclonal Antibody to Heparanase (HPSE) | WB; IHC; ICC; IP. |
LAA711Ra71 | Biotin-Linked Polyclonal Antibody to Heparanase (HPSE) | WB; IHC; ICC. |
MAA711Ra21 | Monoclonal Antibody to Heparanase (HPSE) | WB; IHC; ICC; IP. |
MAA711Ra24 | Monoclonal Antibody to Heparanase (HPSE) | WB |
MAA711Ra22 | Monoclonal Antibody to Heparanase (HPSE) | WB; IHC; ICC; IP. |
MAA711Ra23 | Monoclonal Antibody to Heparanase (HPSE) | WB; IHC; ICC; IP. |
SEA711Ra | ELISA Kit for Heparanase (HPSE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA711Ra | Multiplex Assay Kit for Heparanase (HPSE) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |