Multiplex Assay Kit for Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay)

INH-B

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-101 93
EDTA plasma(n=5) 92-105 101
heparin plasma(n=5) 91-105 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 95-104% 79-101% 85-95%
EDTA plasma(n=5) 93-101% 91-99% 97-105% 83-104%
heparin plasma(n=5) 94-103% 84-96% 97-104% 83-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:INHB) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Adv Med Sci. Are anti-MĂźllerian hormone and its receptor polymorphism associated with the hormonal condition of undescended testes? Pubmed:27162065
Chemosphere. Gestational and lactational exposure to bisphenol AF in maternal rats increases testosterone levels in 23-day-old male offspring. pubmed:27567155
PLoS One Overexpression of ubiquitin carboxyl-terminal hydrolase 1 (UCHL1) in boys with cryptorchidism Pubmed:29401475
Journal of Ovarian Research Comparison of the influence of three fibroid treatment options: supracervical hysterectomy, ulipristal acetate and uterine artery embolization on ovarian … Pubmed:29859107
Stem Cell Research & Therapy Endometrial mesenchymal stem cells isolated from menstrual blood repaired epirubicin-induced damage to human ovarian granulosa cells by inhibiting the … Pubmed: 30606243
Endocrinology Diabetes Type 1 Negatively Influences Leydig Cell Function in Rats, Which is Partially Reversible By Insulin Treatment 33507237
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA760Hu01 Recombinant Inhibin B (INHB) Positive Control; Immunogen; SDS-PAGE; WB.
SEA760Hu ELISA Kit for Inhibin B (INHB) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA760Hu ELISA Kit for Inhibin B (INHB) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA760Hu Multiplex Assay Kit for Inhibin B (INHB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.