Multiplex Assay Kit for Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay)

PAPP-A; PAPA; ASBABP2; DIPLA1; IGFBP-4ase; PAPPA1; Pappalysin 1; Insulin-Like Growth Factor Binding Protein-4 Protease; Differentially Placenta 1 Expressed Protein

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-105 101
EDTA plasma(n=5) 92-101 96
heparin plasma(n=5) 88-105 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 80-90% 90-98% 85-98%
EDTA plasma(n=5) 82-91% 90-99% 95-102% 80-96%
heparin plasma(n=5) 89-98% 93-104% 90-98% 83-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PAPPA) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
American Journal of Physiology-Endocrinology and Metabolism Hyperandrogenism and insulin resistance induce gravid uterine defects in association with mitochondrial dysfunction and aberrant ROS production Pubmed: 30860876
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA800Hu03 Recombinant Pregnancy Associated Plasma Protein A (PAPPA) Positive Control; Immunogen; SDS-PAGE; WB.
RPA800Hu01 Recombinant Pregnancy Associated Plasma Protein A (PAPPA) Positive Control; Immunogen; SDS-PAGE; WB.
RPA800Hu05 Recombinant Pregnancy Associated Plasma Protein A (PAPPA) Positive Control; Immunogen; SDS-PAGE; WB.
APA800Hu01 Active Pregnancy Associated Plasma Protein A (PAPPA) Cell culture; Activity Assays.
APA800Hu02 Active Pregnancy Associated Plasma Protein A (PAPPA) Cell culture; Activity Assays.
APA800Hu03 Active Pregnancy Associated Plasma Protein A (PAPPA) Cell culture; Activity Assays.
RPA800Hu04 Recombinant Pregnancy Associated Plasma Protein A (PAPPA) Positive Control; Immunogen; SDS-PAGE; WB.
APA800Hu04 Active Pregnancy Associated Plasma Protein A (PAPPA) Cell culture; Activity Assays.
RPA800Hu02 Recombinant Pregnancy Associated Plasma Protein A (PAPPA) Positive Control; Immunogen; SDS-PAGE; WB.
PAA800Hu01 Polyclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB; IHC; ICC; IP.
PAA800Hu02 Polyclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB,IHC; FCM
PAA800Hu03 Polyclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB; IHC; ICC; IP.
LAA800Hu71 Biotin-Linked Polyclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB; IHC; ICC.
MAA800Hu21 Monoclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB; IHC; ICC; IP.
MAA800Hu22 Monoclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB; IHC; ICC; IP.
MAA800Hu24 Monoclonal Antibody to Pregnancy Associated Plasma Protein A (PAPPA) WB; IHC; ICC; IP.
SEA800Hu ELISA Kit for Pregnancy Associated Plasma Protein A (PAPPA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA800Hu Multiplex Assay Kit for Pregnancy Associated Plasma Protein A (PAPPA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.