Multiplex Assay Kit for Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay)

Lp(a); AK38; APOA; LP; Sinking Pre-β-Lipoprotein

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-103 85
EDTA plasma(n=5) 91-104 97
heparin plasma(n=5) 97-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-105% 86-104% 83-101% 79-91%
EDTA plasma(n=5) 87-105% 80-99% 84-101% 81-95%
heparin plasma(n=5) 90-97% 97-104% 84-95% 84-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:Lpa) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Molecular Sciences Pigment Epithelium-Derived Factor (PEDF) Protects Osteoblastic Cell Line from Glucocorticoid-Induced Apoptosis via PEDF-R Pubmed:27187377
Evidence-Based Complementary and Alternative Medicine Danshen (Salvia miltiorrhiza) Compounds Improve the Biochemical Indices of the Patients with Coronary HeartDisease. Pubmed:27366196
INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY Lysophosphatidic Acid Regulates the Differentiation of Th2 Cells and Its Antagonist Suppresses Allergic Airway Inflammation Pubmed: 32846422
BMC Gastroenterol Evaluation of serum ATX and LPA as potential diagnostic biomarkers in patients with pancreatic cancer 33568105
blood advances The binding of autotaxin to integrins mediates hyperhomocysteinemia-potentiated platelet activation and thrombosis 34559203
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA842Hu01 Active Lipoprotein, a (Lpa) Cell culture; Activity Assays.
RPA842Hu01 Recombinant Lipoprotein, a (Lpa) Positive Control; Immunogen; SDS-PAGE; WB.
PAA842Hu01 Polyclonal Antibody to Lipoprotein, a (Lpa) WB; IHC; ICC; IP.
MAA842Hu22 Monoclonal Antibody to Lipoprotein, a (Lpa) WB; IHC; ICC; IP.
SEA842Hu ELISA Kit for Lipoprotein, a (Lpa) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA842Hu Multiplex Assay Kit for Lipoprotein, a (Lpa) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.