Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay)
SCGB1A1; CC10; CCSP; UGB; UG; Uteroglobin; Uteroglobin; Urinary Protein 1; Clara Cell Secretory Protein; Secretoglobin Family 1A Member 1; Clara-Cell Specific 10-kD Protein
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA857Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, lung lavage fluid, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range4.88-5000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.627 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 405
US$ 420
US$ 443
US$ 475
US$ 506
US$ 552
US$ 622
Result
For more details, please contact local distributors! US$ 778 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-104 | 89 |
EDTA plasma(n=5) | 97-105 | 101 |
heparin plasma(n=5) | 86-101 | 89 |
sodium citrate plasma(n=5) | 82-96 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-101% | 83-97% | 81-94% | 82-92% |
EDTA plasma(n=5) | 85-101% | 96-104% | 97-105% | 88-97% |
heparin plasma(n=5) | 78-96% | 88-105% | 78-101% | 94-103% |
sodium citrate plasma(n=5) | 86-98% | 91-99% | 80-91% | 78-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:CC16) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Life Science Journal | Pulmonary functions and blood biochemical markers for workers with and without coal worker pneumoconiosis Sciencepub: Source |
Current Therapeutic Research | Analysis of the Protective Biochemical and Pathologic Effects of Aminoguanidine on an Experimental Aspiration Pneumonitis Model Induced by Bile Acids PubMed: S0011393X12000562 |
J Thorac Dis. | Effects of leflunomide on inflamation and fibrosis in bleomycine induced pulmonary fibrosis in wistar albino rats Pubmed: 24255778 |
J Mol Histol. | The therapeutic effects of anti-oxidant and anti-inflammatory drug quercetin on aspiration-induced lung injury in rats Pubmed: 24122261 |
Hum Exp Toxicol January | The effects of α-tocopherol on oxidative damage and serum levels of Clara cell protein 16 in aspiration pneumonitis induced by bile acids Pubmed: 23023024 |
Journal of Thoracic Disease | The evaluation of different treatment protocols for trauma-induced lung injury in rats Pubmed: 24605218 |
PLOS ONE | Susceptibility to COPD: Differential Proteomic Profiling after Acute Smoking Pubmed:25036363 |
PLoS One | Urine proteome analysis by C18 plate–matrix-assisted laser desorption/ionization time-of-flight mass spectrometry allows noninvasive differential diagnosis … Pubmed:30024955 |
Bioscience Reports | N-Acetylcysteine inhalation improves pulmonary function in patients received Liver Transplantation. Doi: 10.1042/BSR20180858 |
biorxiv | Mechanical activation of TRPV4 channels controls albumin reabsorption by proximal tubule cells. |
Analytica Chimica Acta | An ultrasensitive electrochemical detection of tryptase using 3D macroporous reduced graphene oxide nanocomposites by one-pot electrochemical synthesis |
Effects of mammary nutrient demand on glucose kinetics of dairy cows in early lactation | |
Biotech Histochem | Role of bone marrow-derived mesenchymal stem cells in alleviating pulmonary epithelium damage and extracellular matrix remodeling in a rat model of lung fibrosis … Pubmed: 32909452 |
OBESITY SURGERY | The Protective Effects of Butorphanol on Pulmonary Function of Patients with Obesity Undergoing Laparoscopic Bariatric Surgery: a Double-Blind Randomized … Pubmed: 32535786 |
Respir Res | Elevated plasma levels of epithelial and endothelial cell markers in COVID-19 survivors with reduced lung diffusing capacity six months after hospital … Pubmed:35189887 |
Drug Des Devel Ther | Lung-Protective Effects of Lidocaine Infusion on Patients with Intermediate/High Risk of Postoperative Pulmonary Complications: A Double-Blind Randomized … Pubmed:35422611 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
APA857Mu01 | Active Clara Cell Protein 16 (CC16) | Cell culture; Activity Assays. |
RPA857Mu01 | Recombinant Clara Cell Protein 16 (CC16) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA857Mu02 | Recombinant Clara Cell Protein 16 (CC16) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA857Mu01 | Polyclonal Antibody to Clara Cell Protein 16 (CC16) | WB; IHC; ICC; IP. |
PAA857Mu02 | Polyclonal Antibody to Clara Cell Protein 16 (CC16) | WB; IHC; ICC; IP. |
LAA857Mu81 | FITC-Linked Polyclonal Antibody to Clara Cell Protein 16 (CC16) | WB; IHC; ICC; IF. |
LAA857Mu71 | Biotin-Linked Polyclonal Antibody to Clara Cell Protein 16 (CC16) | WB; IHC; ICC. |
SEA857Mu | ELISA Kit for Clara Cell Protein 16 (CC16) | Enzyme-linked immunosorbent assay for Antigen Detection. |