Multiplex Assay Kit for Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay)
angiotensinogenase
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA889Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 427
US$ 443
US$ 468
US$ 501
US$ 534
US$ 583
US$ 657
Result
For more details, please contact local distributors! US$ 821 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-94 | 90 |
EDTA plasma(n=5) | 79-92 | 87 |
heparin plasma(n=5) | 99-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-97% | 99-105% | 88-95% | 81-89% |
EDTA plasma(n=5) | 80-91% | 93-105% | 82-96% | 81-101% |
heparin plasma(n=5) | 94-105% | 97-104% | 83-95% | 95-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:REN) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Hypertension | Prenatal overexposure to glucocorticoids programs renal 11β-hydroxysteroid dehydrogenase type 2 expression and salt-sensitive hypertension in the rat PubMed: 21045727 |
The Journal of Physiology | Recombinant human erythropoietin in humans down-regulates proximal renal tubular reabsorption and causes a fall in glomerular filtration rate Physoc: 194241 |
The Journal of Physiology | Erythropoietin down‐regulates proximal renal tubular reabsorption and causes a fall in glomerular filtration rate in humans PubMed: 20724370 |
Pathobiology | Anti-Angiotensin and Hypoglycemic Treatments Suppress Liver Metastasis of Colon Cancer Cells Karger: 000330169 |
Journal of Cardiovascular Pharmacology | The Angiotensin Receptor Blocker, Azilsartan Medoxomil (TAK-491), Suppresses Vascular Wall Expression of Plasminogen Activator Inhibitor Type-I Protein Potentially Facilitating the Stabilization of Atherosclerotic Plaques LWW: 08000 |
Kidney International | Multiple and large simple renal cysts are associated with prehypertension and hypertension. Pubmed: 23389415 |
Human Physiology | Estimation of the parameters of the renin-angiotensin-aldosterone system, water-electrolyte metabolism, and endothelial function in newborns of women with chronic hypertension Springer:Source |
Journal of Pharmacological Sciences | Organ-Specific Activation of the Gastric Branch of the Efferent Vagus Nerve by Ghrelin in Urethane-Anesthetized Rats Pubmed:24366191 |
Liver International | VSL#3 probiotic treatment decreases bacterial translocation in rats with carbon tetrachloride-induced cirrhosis Pubmed:24750552 |
Gynecological Endocrinology | Immunological and hemostasiological disorders in women with ovarian hyperstimulation syndrome Pubmed:25200828 |
Oxidative Medicine and Cellular Longevity | Age-Associated Changes in the Vascular Renin-Angiotensin System in Mice Pubmed:27200147 |
PLoS One | Ablation of Potassium-Chloride Cotransporter Type 3 (Kcc3) in Mouse Causes Multiple Cardiovascular Defects and Isosmotic Polyuria Pubmed:27166674 |
PLOS ONE | Reduced Expression of the Extracellular Calcium-Sensing Receptor (CaSR) Is Associated withActivation of the Renin-Angiotensin System (RAS) to Promote Vascular Remodeling in the Pathogenesis of Essential Hypertension. pubmed:27391973 |
Heart Lung Circ. | Efficacy and Safety of Renal Sympathetic Denervation on Dogs with Pressure Overload-Induced Heart Failure. pubmed:27555054 |
European Journal of Pharmaceutical Sciences | Sacubitril/valsartan (LCZ696) Significantly Reduces Aldosterone and Increases cGMP Circulating Levels in a Canine Model of RAAS Activation Doi: 10.1101/435560 |
Nutrition | Gut Dysbiosis Contribute to High Fructose Induced Salt Sensitive Hypertension In Sprague-Dawley Rats |
ACTA PHARMACOLOGICA SINICA | The vascular endothelial growth factor trap aflibercept induces vascular dysfunction and hypertension via attenuation of eNOS/NO signaling in mice 33303990 |
Hypertens Res | Association of Ang-(1¨C7) and des-Arg 9 BK as new biomarkers of obesity and cardiometabolic risk factors in adolescents 33568792 |
Phosphorylation of β1-integrin in juxtaglomerular cells helps control blood pressure during the progression of diabetic nephropathy | |
Bedeutung des intrarenalen Renin-Angiotensin-Systems f¨¹r die Entwicklung der chronischen Nierenkrankheit |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA889Ra02 | Recombinant Renin (REN) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA889Ra01 | Recombinant Renin (REN) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA889Ra02 | Polyclonal Antibody to Renin (REN) | WB; IHC; ICC; IP. |
PAA889Ra01 | Polyclonal Antibody to Renin (REN) | WB; IHC; ICC; IP. |
LAA889Ra71 | Biotin-Linked Polyclonal Antibody to Renin (REN) | WB; IHC; ICC. |
MAA889Ra21 | Monoclonal Antibody to Renin (REN) | WB; IHC; ICC; IP. |
MAA889Ra23 | Monoclonal Antibody to Renin (REN) | WB; IHC; ICC; IP. |
MAA889Ra22 | Monoclonal Antibody to Renin (REN) | WB; IHC; ICC; IP. |
SEA889Ra | ELISA Kit for Renin (REN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA889Ra | CLIA Kit for Renin (REN) | Chemiluminescent immunoassay for Antigen Detection. |
LMA889Ra | Multiplex Assay Kit for Renin (REN) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |