Multiplex Assay Kit for Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay)

Cholecalciferol; Toxiferol; Activated 7-Dehydrocholesterol

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-97 94
EDTA plasma(n=5) 80-103 97
heparin plasma(n=5) 90-104 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 97-105% 84-95% 96-103%
EDTA plasma(n=5) 89-99% 97-104% 91-105% 78-105%
heparin plasma(n=5) 85-94% 93-101% 89-99% 88-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:VD3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Life Sciences Research Impact of Curcumin and Flaxseed Oil on Bone Turnover in Glucocorticoid-Injected Female Rats profile:303311214
Protective Effect of Soybean and Mushroom against Glucocorticoid-Induced Osteoporosis in Female Rats :
Gaceta Medica De Mexico Deficiencia de vitamina D en madres y neonatos mexicanos pubmed:29099117
Cellular Physiology and Biochemistry P38/TRHr-Dependent Regulation of TPO in Thyroid Cells Contributes to the Hypothyroidism of Triclosan-Treated Rats Pubmed:29462796
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPA920Ge11 BSA Conjugated Vitamin D3 (VD3) Immunogen; SDS-PAGE; WB.
CPA920Ge21 OVA Conjugated Vitamin D3 (VD3) Immunogen; SDS-PAGE; WB.
PAA920Ge01 Polyclonal Antibody to Vitamin D3 (VD3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA920Ge71 Biotin-Linked Polyclonal Antibody to Vitamin D3 (VD3) WB; IHC; ICC.
MAA920Ge21 Monoclonal Antibody to Vitamin D3 (VD3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA920Ge ELISA Kit for Vitamin D3 (VD3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA920Ge Multiplex Assay Kit for Vitamin D3 (VD3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA920Ge11 ELISA Kit DIY Materials for Vitamin D3 (VD3) Main materials for "Do It (ELISA Kit) Yourself".