Multiplex Assay Kit for Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay)

P4HB; ERBA2L; PDIA1; PO4DB; PROHB, DSI, GIT, PDI, PO4HB, P4Hbeta; Prolyl 4-Hydroxylase Subunit Beta; Procollagen-Proline 2-Oxoglutarate 4-Dioxygenase Beta Polypeptide

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-96 89
EDTA plasma(n=5) 90-97 93
heparin plasma(n=5) 96-103 99
sodium citrate plasma(n=5) 84-92 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-91% 92-105% 89-101% 83-91%
EDTA plasma(n=5) 86-97% 87-104% 89-96% 84-97%
heparin plasma(n=5) 78-94% 80-89% 79-101% 93-102%
sodium citrate plasma(n=5) 96-103% 81-91% 82-102% 90-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PDI) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Chromatographia A Proteomic-Based Approach to Study the Mechanism of Cytotoxicity Induced by Interleukin-1α and Cycloheximide article:10.1007
PLoS One Tunable activation of therapeutic platelet-rich plasma by pulse electric field: Differential effects on clot formation, growth factor release, and platelet … Pubmed: 30256831
CALCIUM CONTROLLED ACTIVATION OF PLATELETS VIA ELECTRICAL STIMULATION
Aging (Albany NY) Endothelial microparticle-associated protein disulfide isomerase increases platelet activation in diabetic coronary heart disease 34285139
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APB061Hu01 Active Protein Disulfide Isomerase (PDI) Cell culture; Activity Assays.
RPB061Hu01 Recombinant Protein Disulfide Isomerase (PDI) Positive Control; Immunogen; SDS-PAGE; WB.
PAB061Hu01 Polyclonal Antibody to Protein Disulfide Isomerase (PDI) WB
MAB061Hu22 Monoclonal Antibody to Protein Disulfide Isomerase (PDI) WB; IHC; ICC; IP.
SEB061Hu ELISA Kit for Protein Disulfide Isomerase (PDI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB061Hu Multiplex Assay Kit for Protein Disulfide Isomerase (PDI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.