Multiplex Assay Kit for Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay)

DNaseI; DNL1; DRNI; DNase-I; Dornase alfa

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-101 94
EDTA plasma(n=5) 90-104 98
heparin plasma(n=5) 89-99 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 91-99% 88-98% 91-103%
EDTA plasma(n=5) 95-103% 78-101% 97-104% 78-91%
heparin plasma(n=5) 98-105% 80-104% 85-92% 81-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:DNASE1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
J Card Fail Low Circulating Levels of Mitochondrial and High Levels of Nuclear DNA Predict Mortality in Chronic Heart Failure Pubmed:27349571
Biochimie Inhibition of nuclease activity by a splice-switching oligonucleotide targeting deoxyribonuclease 1 mRNA prevents apoptosis progression and prolong viability of … Pubmed: 32315661
Scientific Reports Biomarkers of neutrophil extracellular traps (NETs) and nitric oxide-(NO)-dependent oxidative stress in women who miscarried Pubmed: 32753622
J Am Heart Assoc DNase 1 Protects From Increased Thrombin Generation and Venous Thrombosis During Aging: Cross‐Sectional Study in Mice and Humans Pubmed:35023342
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB127Mu02 Recombinant Deoxyribonuclease I (DNASE1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB127Mu01 Recombinant Deoxyribonuclease I (DNASE1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB127Mu01 Polyclonal Antibody to Deoxyribonuclease I (DNASE1) WB; IHC; ICC; IP.
PAB127Mu02 Polyclonal Antibody to Deoxyribonuclease I (DNASE1) WB; IHC; ICC; IP.
SEB127Mu ELISA Kit for Deoxyribonuclease I (DNASE1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB127Mu Multiplex Assay Kit for Deoxyribonuclease I (DNASE1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.