Multiplex Assay Kit for Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay)

PL; Plasmin; Activation peptide; Angiostatin

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-104 99
EDTA plasma(n=5) 92-99 95
heparin plasma(n=5) 95-105 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-98% 79-98% 86-96% 96-103%
EDTA plasma(n=5) 80-89% 90-104% 78-105% 80-104%
heparin plasma(n=5) 84-103% 81-90% 84-94% 89-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:Plg) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Molecular Sciences The Anticoagulant Effect of PGI2S and tPA in Transgenic Umbilical Vein Endothelial Cells Is Linked to Up-Regulation of PKA and PKC Mdpi: Source
J Anim Physiol Anim Nutr (Berl). Improved milk production through PG-PL system by provision of in-house shelter management in lactating Murrah buffaloes during winter season. pubmed:28084661
Neurotherapeutics iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448
Veterinarski Arhiv The influence of a modified micro-environment on stress and milk production through the plasminogen-plasmin system in Murrah buffaloes during the hot-humid … 10.24099:vet.arhiv.170113
Food Bioscience Reducing antigenicity of ¦Â-lactoglobulin, probiotic properties and safety evaluation of Lactobacillus plantarum AHQ-14 and Lactobacillus bulgaricus BD0390
Foods Antigenicity and Safety Evaluation of Lactiplantibacillus plantarum 7-2 Screened to Reduce α-Casein Antigen Pubmed:35010214
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB236Ra01 Recombinant Plasminogen (Plg) Positive Control; Immunogen; SDS-PAGE; WB.
APB236Ra01 Active Plasminogen (Plg) Cell culture; Activity Assays.
PAB236Ra01 Polyclonal Antibody to Plasminogen (Plg) WB; IHC; ICC; IP.
MAB236Ra21 Monoclonal Antibody to Plasminogen (Plg) WB; IHC; ICC; IP.
MAB236Ra22 Monoclonal Antibody to Plasminogen (Plg) WB; IHC; ICC; IP.
SEB236Ra ELISA Kit for Plasminogen (Plg) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB236Ra Multiplex Assay Kit for Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB236Ra01 ELISA Kit DIY Materials for Plasminogen (Plg) Main materials for "Do It (ELISA Kit) Yourself".