Multiplex Assay Kit for Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay)
Hgb; Haemoglobin; Heterotetramer(αβ)2
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB409Gu
- Organism SpeciesCavia (Guinea pig ) Same name, Different species.
- Sample TypeSerum, plasma, erythrocyte lysates.
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.78-800ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.26 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 348
US$ 362
US$ 382
US$ 409
US$ 436
US$ 476
US$ 536
Result
For more details, please contact local distributors! US$ 670 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-105 | 102 |
EDTA plasma(n=5) | 78-102 | 95 |
heparin plasma(n=5) | 90-102 | 98 |
sodium citrate plasma(n=5) | 83-101 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-105% | 96-104% | 90-104% | 82-104% |
EDTA plasma(n=5) | 89-98% | 92-101% | 78-103% | 78-90% |
heparin plasma(n=5) | 86-94% | 96-104% | 91-98% | 84-101% |
sodium citrate plasma(n=5) | 78-91% | 88-95% | 81-93% | 96-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:HB) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Comparative Biochemistry and Physiology Part C: Toxicology & Pharmacology | Effects of ectoine on behavioural, physiological and biochemical parameters of Daphnia magna Pubmed:25460046 |
PLoS One. | Comparative Proteomics Identifies Host Immune System Proteins Affected by Infection with Mycobacterium bovis Pubmed:27027307 |
Parasites & Vectors | The intracellular bacterium Anaplasma phagocytophilum selectively manipulates the levels of vertebrate host proteins in the tick vector Ixodes scapularis. pubmed:27561965 |
Proteomics. Clinical Applications | Elevated levels of protein AMBP in cerebrospinal fluid of women with preeclampsia compared to normotensive pregnant women. pubmed:27615121 |
Molecular nutrition & food research | Chicory inulin ameliorates type 2 diabetes mellitus and suppresses JNK and MAPK pathways in vivo and in vitro pubmed:28105758 |
Frontiers in Immunology | Oxidized Hemoglobin Is Antigenic and Immunogenic in Lupus pubmed:28694810 |
新規人工酸素運搬体HemoAct を用いた脳虚血再灌流障害治療開発に関する研究 : | |
Acta Neuropathologica Communications | Mural cell-derived laminin-α5 plays a detrimental role in ischemic stroke Pubmed: 30777135 |
Angiogenesis | Decylubiquinone suppresses breast cancer growth and metastasis by inhibiting angiogenesis via the ROS/p53/BAI1 signaling pathway Pubmed: 32020421 |
Food Bioscience | Water-extractable zinc protoporphyrin IX in Parma ham predominantly exists as complexes with hemoglobin and myoglobin |
Photochem Photobiol | Effects of Human Serum Albumin on the Fluorescence Intensity and Tumor Imaging Properties of IR‐780 Dye 34687567 |
Catalog No. | Related products for research use of Cavia (Guinea pig ) Organism species | Applications (RESEARCH USE ONLY!) |
NPB409Gu01 | Native Hemoglobin (HB) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB409Gu01 | Polyclonal Antibody to Hemoglobin (HB) | WB; IHC; ICC; IP. |
LAB409Gu71 | Biotin-Linked Polyclonal Antibody to Hemoglobin (HB) | WB; IHC; ICC. |
SEB409Gu | ELISA Kit for Hemoglobin (HB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB409Gu | Multiplex Assay Kit for Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |