Multiplex Assay Kit for B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay)

CXCL13; SCYB13; BCA1; BLR1L; ANGIE; ANGIE2; Chemokine(C-X-C-Motif)ligand 13; Small Inducible Cytokine B Subfamily(Cys-X-Cys Motif)Member 13

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-93 88
EDTA plasma(n=5) 95-103 99
heparin plasma(n=5) 81-101 86
sodium citrate plasma(n=5) 82-101 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-101% 87-102% 86-99% 91-101%
EDTA plasma(n=5) 83-94% 94-102% 95-103% 84-103%
heparin plasma(n=5) 79-89% 88-97% 79-102% 78-92%
sodium citrate plasma(n=5) 86-102% 79-99% 89-97% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:BLC) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE Possible Anti-inflammatory Effects of Mesenchymal Stem Cells Transplantation via Changes in CXCL8 Levels in Patients with Refractory Rheumatoid Arthritis
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB601Ra01 Recombinant B-Lymphocyte Chemoattractant (BLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAB601Ra01 Polyclonal Antibody to B-Lymphocyte Chemoattractant (BLC) WB; IHC; ICC; IP.
MAB601Ra21 Monoclonal Antibody to B-Lymphocyte Chemoattractant (BLC) WB; IHC; ICC; IP.
SEB601Ra ELISA Kit for B-Lymphocyte Chemoattractant (BLC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB601Ra CLIA Kit for B-Lymphocyte Chemoattractant (BLC) Chemiluminescent immunoassay for Antigen Detection.
LMB601Ra Multiplex Assay Kit for B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.