Multiplex Assay Kit for Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay)
Tn-T; TNNT
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB820Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 474
US$ 492
US$ 520
US$ 556
US$ 593
US$ 648
US$ 730
Result
For more details, please contact local distributors! US$ 912 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-105 | 101 |
EDTA plasma(n=5) | 90-101 | 94 |
heparin plasma(n=5) | 85-95 | 90 |
sodium citrate plasma(n=5) | 95-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-99% | 97-105% | 79-96% | 96-105% |
EDTA plasma(n=5) | 98-105% | 79-95% | 79-104% | 80-101% |
heparin plasma(n=5) | 80-104% | 88-98% | 93-101% | 92-101% |
sodium citrate plasma(n=5) | 80-104% | 89-97% | 92-99% | 86-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:TNT) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
IJC Heart & Vasculature | Cardiovascular changes in patients with non-severe Plasmodium vivax malaria article:S2352-9067(16)30010-0 |
Journal of the American Heart Association | Postinfarction Hearts Are Protected by Premature Senescent Cardiomyocytes Via GATA 4‐Dependent CCN 1 Secretion |
Experimental Gerontology | Neural control of postural sway: relationship to strength measures in young and elderly adults Pubmed: 30630036 |
Nature Communications | Preclinical development of a miR-132 inhibitor for heart failure treatment Pubmed: 32005803 |
Scientific Reports | Cardioprotective effect of grape polyphenol extract against doxorubicin induced cardiotoxicity Pubmed: 32895481 |
Molecular Medicine Reports | The mRNA expression of Il6 and Pdcd1 are predictive and protective factors for doxorubicin?induced cardiotoxicity 33300057 |
Cell Metabolism | Pharmacological inhibition of arachidonate 12-lipoxygenase ameliorates myocardial ischemia-reperfusion injury in multiple species 34536344 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
SEB820Ra | ELISA Kit for Troponin T (TNT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB820Ra | Multiplex Assay Kit for Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |