Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay)
APLN36
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB865Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.59-600pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.197 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 415
US$ 431
US$ 455
US$ 487
US$ 519
US$ 567
US$ 638
Result
For more details, please contact local distributors! US$ 798 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-98 | 85 |
EDTA plasma(n=5) | 87-94 | 91 |
heparin plasma(n=5) | 78-103 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 83-102% | 96-105% | 86-94% | 87-99% |
EDTA plasma(n=5) | 97-105% | 78-97% | 93-101% | 91-101% |
heparin plasma(n=5) | 80-98% | 92-105% | 96-103% | 99-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:AP36) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
European Journal of Obstetrics & Gynecology and Reproductive Biology | Apelin levels in relation with hormonal and metabolic profile in patients with polycystic ovary syndrome ScienceDirect: S0301211514000931 |
Eur J Obstet Gynecol Reprod Biol. | Apelin?levels?in?relation?with?hormonal?and metabolic profile in patients with polycystic ovary syndrome. Pubmed:24642195 |
J Obstet Gynaecol Res. | Apelin?levels are higher in obese patients with?endometrial?cancer. Pubmed:25160885 |
Disease Markers | Apelin and Atrial Fibrillation: The Role in the Arrhythmia Recurrence Prognosis Pubmed:29721104 |
Clinical and Experimental Hypertension | Serum concentrations of apelin-17 isoform vary in accordance to blood pressure categories in individuals with obesity class 3 Pubmed:29652188 |
Acta Cardiologica Sinica | The Relationship between Serum Apelin Levels and the Severity of Calcific Aortic Stenosis Pubmed:29844647 |
Disease Markers | Find the Essence through the Phenomena: Cardiovascular Diseases and Biomarkers Pubmed: 30034556 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
CEB865Hu | ELISA Kit for Apelin 36 (AP36) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB865Hu | Multiplex Assay Kit for Apelin 36 (AP36) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |