Multiplex Assay Kit for Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD340; EGFR2; HER-2/neu; HER2; NEU; MLN 19; NGL; TKR1; p185; Epidermal Growth Factor Receptor 2; V-Erb-B2 Erythroblastic Leukemia Viral Oncogene Homolog 2; Neuro/Glioblastoma Derived Oncogene Homolog

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-96 91
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 90-98 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 89-98% 98-105% 93-101%
EDTA plasma(n=5) 80-97% 95-105% 88-103% 85-97%
heparin plasma(n=5) 80-99% 98-105% 85-96% 78-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ErbB2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neuroscience Letter Therapeutic effect of co-transplantation of neuregulin 1-transfected-Schwann cells and bone marrow stromal cells on spinal cord hemisection syndrom Cyagen: source
Journal of Electroanalytical Chemistry A highly sensitive label-free electrochemical immunosensor based on AuNPs-PtNPs-MOFs for nuclear matrix protein 22 analysis in urine sample
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB867Hu01 Recombinant Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) Positive Control; Immunogen; SDS-PAGE; WB.
APB867Hu01 Active Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) Cell culture; Activity Assays.
RPB867Hu02 Recombinant Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) Positive Control; Immunogen; SDS-PAGE; WB.
PAB867Hu02 Polyclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
PAB867Hu01 Polyclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
LAB867Hu81 FITC-Linked Polyclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IF.
LAB867Hu71 Biotin-Linked Polyclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC.
MAB867Hu24 Monoclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
MAB867Hu27 Monoclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
MAB867Hu29 Monoclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
MAB867Hu23 Monoclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
MAB867Hu21 Monoclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
MAB867Hu22 Monoclonal Antibody to Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) WB; IHC; ICC; IP.
SEB867Hu ELISA Kit for Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB867Hu Multiplex Assay Kit for Receptor Tyrosine Protein Kinase erbB-2 (ErbB2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.