Multiplex Assay Kit for Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay)

APLN13

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-104 99
EDTA plasma(n=5) 90-104 97
heparin plasma(n=5) 93-102 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-101% 98-105% 82-105% 86-102%
EDTA plasma(n=5) 84-93% 87-104% 92-105% 78-103%
heparin plasma(n=5) 78-95% 84-101% 78-97% 78-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AP13) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Investigative Ophthalmology and Visual Science Apelin in Plasma and Vitreous and in Fibrovascular Retinal Membranes of Patients with Proliferative Diabetic Retinopathy IOVS: 4237
Asian Pacific Journal of Cancer Prevention Is short-term exercise a therapeutic tool for improvement of cardioprotection against DOX-induced cardiotoxicity? An experimental controlled protocol in rats. Apjcpcontrol: Source
Clin Exp Hypertens Individual and concomitant effects of cardioprotective programs on cardiac apelinergic system and oxidative state in L-NAME-induced hypertension. PubMed: 22578103
Medical Science Monitor : International Medical Journal of Experimental and Clinical Research Effect of Ramadan fasting on serum concentration of apelin-13 and new obesity indices in healthy adult men NCBI: PMC3943714
ZJRMS Improvement of Kidney Apelin and Apelin Receptor in Nitro-L-Arginine-Methyl Ester Induced Rats Zjrms:Source
Iranian Journal of Kidney Diseases The Role of Apelin 13 in Progression of Chronic Kidney Disease. PubMed: 26338160
 Journal of Clinical & Experimental Nephrology Role of Circulating Serum Apelin-13 Levels in Glomerulonephritis: A Pilot Study aid:8469
international journal of cardiology Biochemical and genetic role of apelin in essential hypertension and acute coronarysyndrome. pubmed:27543713
Clinical and Experimental Hypertension Serum concentrations of apelin-17 isoform vary in accordance to blood pressure categories in individuals with obesity class 3 Pubmed:29652188
Progress in Nutrition Effect of fermented food consumption on biochemical parameters and adipokines levels Doi: 0.23751/pn.v20i4.7374
ACTA CARDIOLOGICA SINICA Impact of apelin-13 on the development of coronary artery ectasia Pubmed: 32425436
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
SPB887Hu01 Synthetic Apelin 13 (AP13) Immunogen; Blocking Peptide.
CEB887Hu ELISA Kit for Apelin 13 (AP13) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB887Hu Multiplex Assay Kit for Apelin 13 (AP13) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.