Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay)
HRG4; Pro-NRG4; Pro-neuregulin-4, membrane-bound isoform
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC174Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 449
US$ 467
US$ 492
US$ 527
US$ 562
US$ 613
US$ 691
Result
For more details, please contact local distributors! US$ 864 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 94-105 | 99 |
EDTA plasma(n=5) | 84-94 | 89 |
heparin plasma(n=5) | 92-105 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-95% | 81-96% | 78-91% | 84-102% |
EDTA plasma(n=5) | 81-90% | 92-101% | 78-101% | 99-105% |
heparin plasma(n=5) | 81-89% | 78-90% | 91-104% | 86-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:NRG4) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Metabolism | A case–control study: Association between serum neuregulin 4 level and non-alcoholic fatty liver disease PubMed: 26476959 |
Diabetes Research and Clinical Practice | Comparison of serum NeureCavia (Guinea pig )lin 4 (Nrg4) levels in adults with newly diagnosed type 2 diabetes mellitus and controls without diabetes Pubmed:27329015 |
Scientific Reports | Short-chain fatty acids and inulin, but not guar gum, prevent diet-induced obesity and insulin resistance through differential mechanisms in mice. pubmed:28733671 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPC174Mu01 | Recombinant Neuregulin 4 (NRG4) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPC174Mu02 | Recombinant Neuregulin 4 (NRG4) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC174Mu01 | Polyclonal Antibody to Neuregulin 4 (NRG4) | WB; IHC; ICC; IP. |
PAC174Mu02 | Polyclonal Antibody to Neuregulin 4 (NRG4) | WB; IHC; ICC; IP. |
SEC174Mu | ELISA Kit for Neuregulin 4 (NRG4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC174Mu | Multiplex Assay Kit for Neuregulin 4 (NRG4) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |