Multiplex Assay Kit for Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay)

LEFTY-B; LEFTYB; LEFT-B; LEFTB; Left Right Determination Factor B

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LEFTY1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC175Hu02 Recombinant Left/Right Determination Factor 1 (LEFTY1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC175Hu01 Recombinant Left/Right Determination Factor 1 (LEFTY1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC175Hu03 Recombinant Left/Right Determination Factor 1 (LEFTY1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC175Hu01 Polyclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
PAC175Hu03 Polyclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
PAC175Hu02 Polyclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
FAC175Hu01 Anti-Left/Right Determination Factor 1 (LEFTY1) Polyclonal Antibody Flow cytometry.
FAC175Hu03 Anti-Left/Right Determination Factor 1 (LEFTY1) Polyclonal Antibody Flow cytometry.
FAC175Hu05 Anti-Left/Right Determination Factor 1 (LEFTY1) Polyclonal Antibody Flow cytometry.
MAC175Hu21 Monoclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
MAC175Hu22 Monoclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
LAC175Hu72 Biotin-Linked Monoclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC.
SEC175Hu ELISA Kit for Left/Right Determination Factor 1 (LEFTY1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC175Hu CLIA Kit for Left/Right Determination Factor 1 (LEFTY1) Chemiluminescent immunoassay for Antigen Detection.
LMC175Hu Multiplex Assay Kit for Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSC175Hu01 Antibody Pair for Left/Right Determination Factor 1 (LEFTY1) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSC175Hu01 ELISA Kit DIY Materials for Left/Right Determination Factor 1 (LEFTY1) Main materials for "Do It (ELISA Kit) Yourself".