Multiplex Assay Kit for Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay)

LGALS10; LPPL; Eosinophil Lysophospholipase; Lysolecithin Acylhydrolase; Galectin 10

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 98
EDTA plasma(n=5) 88-96 93
heparin plasma(n=5) 88-103 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-94% 93-101% 79-97% 79-103%
EDTA plasma(n=5) 81-89% 90-99% 97-105% 78-103%
heparin plasma(n=5) 92-99% 99-105% 87-97% 84-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CLC) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Universit Transcriptomics and Immune Profiles of Asymptomatic Filarial-Infected Individuals 2015: 4195
Multiple Sclerosis and Related Disorders Interleukin 1 receptor antagonist and 2′-5′-oligoadenylate synthetase-like molecules as novel biomarkers for multiple sclerosis patients in Bahrain pubmed:29141788
INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY Predictive Significance of Charcot-Leyden Crystal Protein in Nasal Secretions in Recurrent Chronic Rhinosinusitis with Nasal Polyps Pubmed: 32927462
INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY Charcot-Leyden Crystal Protein in Nasal Secretions of Patients with Nonallergic Rhinitis with Eosinophilia Syndrome Pubmed: 32694242
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC387Hu01 Recombinant Charcot Leyden Crystal Protein (CLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAC387Hu01 Polyclonal Antibody to Charcot Leyden Crystal Protein (CLC) WB; IHC; ICC; IP.
LAC387Hu71 Biotin-Linked Polyclonal Antibody to Charcot Leyden Crystal Protein (CLC) WB; IHC; ICC.
MAC387Hu22 Monoclonal Antibody to Charcot Leyden Crystal Protein (CLC) WB; IHC; ICC; IP.
MAC387Hu21 Monoclonal Antibody to Charcot Leyden Crystal Protein (CLC) WB; IHC; ICC; IP.
SEC387Hu ELISA Kit for Charcot Leyden Crystal Protein (CLC) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC387Hu Multiplex Assay Kit for Charcot Leyden Crystal Protein (CLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC387Hu01 ELISA Kit DIY Materials for Charcot Leyden Crystal Protein (CLC) Main materials for "Do It (ELISA Kit) Yourself".