Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay)
PDGF-C; SCDGF; VEGF-E; Fallotein; Spinal cord-derived growth factor; Platelet-derived growth factor C, latent form; Platelet-derived growth factor C, receptor-binding form
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC920Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypePlasma.
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range7.81-8000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.603 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 411
US$ 427
US$ 450
US$ 482
US$ 514
US$ 561
US$ 632
Result
For more details, please contact local distributors! US$ 790 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-104 | 87 |
EDTA plasma(n=5) | 91-99 | 94 |
heparin plasma(n=5) | 99-105 | 102 |
sodium citrate plasma(n=5) | 87-95 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-103% | 88-96% | 86-96% | 89-98% |
EDTA plasma(n=5) | 85-99% | 78-93% | 85-96% | 90-98% |
heparin plasma(n=5) | 95-103% | 90-98% | 96-103% | 79-97% |
sodium citrate plasma(n=5) | 96-104% | 92-102% | 99-105% | 81-90% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PDGFC) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Immunobiology | Platelet derived growth factor-CC secreted by M2 macrophages induces alpha-smooth muscle actin expression by dermal and gingival fibroblasts PubMed: 23182716 |
Physiological Reports | High glucose induces plateletâderived growth factorâC via carbohydrate response elementâbinding protein in glomerular mesangial cells Pubmed:27033449 |
Respiratory Research | Changes in pulmonary endothelial cell properties during bleomycin-induced pulmonary fibrosis Pubmed:29940932 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
EPC920Hu61 | Eukaryotic Platelet Derived Growth Factor C (PDGFC) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPC920Hu01 | Recombinant Platelet Derived Growth Factor C (PDGFC) | Positive Control; Immunogen; SDS-PAGE; WB. |
APC920Hu01 | Active Platelet Derived Growth Factor C (PDGFC) | Cell culture; Activity Assays. |
PAC920Hu01 | Polyclonal Antibody to Platelet Derived Growth Factor C (PDGFC) | WB; IHC; ICC; IP. |
MAC920Hu22 | Monoclonal Antibody to Platelet Derived Growth Factor C (PDGFC) | WB; IHC; ICC; IP. |
SEC920Hu | ELISA Kit for Platelet Derived Growth Factor C (PDGFC) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCC920Hu | CLIA Kit for Platelet Derived Growth Factor C (PDGFC) | Chemiluminescent immunoassay for Antigen Detection. |
LMC920Hu | Multiplex Assay Kit for Platelet Derived Growth Factor C (PDGFC) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |