Multiplex Assay Kit for Cathepsin C (CTSC) ,etc. by FLIA (Flow Luminescence Immunoassay)

CTS-C; DPPI; CPPI; DPP1; DPP-I; HMS; JP; JPD; PALS; PLS; Dipeptidyl Peptidase I; Dipeptidyl transferase; Cathepsin J

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Cathepsin C (CTSC) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cathepsin C (CTSC) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cathepsin C (CTSC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cathepsin C (CTSC) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CTSC) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BMC Medicine Integrating multiple 'omics' analyses identifies serological protein biomarkers for preeclampsia Springer: Source
BioMed Research International Volume Are Proteinase 3 and Cathepsin C Enzymes Related to Pathogenesis of Periodontitis? Pubmed:24949444
Increased levels of malondialdehyde and cathepsin C by Aggregatibacter actinomycetemcomitans in saliva as aggressive periodontitis biomarkers
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC965Hu01 Recombinant Cathepsin C (CTSC) Positive Control; Immunogen; SDS-PAGE; WB.
PAC965Hu01 Polyclonal Antibody to Cathepsin C (CTSC) WB; IHC; ICC; IP.
MAC965Hu22 Monoclonal Antibody to Cathepsin C (CTSC) WB; IHC; ICC; IP.
SEC965Hu ELISA Kit for Cathepsin C (CTSC) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC965Hu Multiplex Assay Kit for Cathepsin C (CTSC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.