Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay)

GSHPX3; GPx-P; GSHPx-P; GPXP; Plasma glutathione peroxidase; Extracellular glutathione peroxidase

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-103 98
EDTA plasma(n=5) 90-104 96
heparin plasma(n=5) 92-99 96
sodium citrate plasma(n=5) 94-102 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 95-102% 89-96% 84-105%
EDTA plasma(n=5) 92-103% 83-97% 80-92% 89-98%
heparin plasma(n=5) 85-102% 80-96% 99-105% 90-102%
sodium citrate plasma(n=5) 80-92% 94-105% 85-99% 83-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GPX3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Reproduction Alteration in the intrafollicular thiol–redox system in infertile women with endometriosis Pubmed:25376627
international journal of cardiology Endothelial function impairment in STEMI patients with out-of-hospital cardiac arrest under therapeutic hypothermia treatment. pubmed:28087172
Current Alzheimer Research Comparison of Extracellular and Intracellular Blood Compartments Highlights Redox Alterations in Alzheimer's and Mild Cognitive Impairment Patients. pubmed:27748187
Frontiers in Microbiology Burn Serum Increases Staphylococcus aureus Biofilm Formation via Oxidative Stress. pubmed:28702016
Clinical and Translational Oncology Hydrogen peroxide-induced mitophagy contributes to laryngeal cancer cells survival via the upregulation of FUNDC1 Pubmed: 30284230
Toxicological Sciences Kidney toxicity and response of selenium containing protein-glutathione peroxidase (Gpx3) to CdTe QDs on different levels Pubmed: 30535317
Available at SSRN 3234834 Human Plasma Protein (s) Based Conceptual Diagnostic Tool for Altitude-Acclimation Assessment
The Journal of Nutritional Biochemistry Dietary selenium deficiency or selenomethionine excess drastically alters organ selenium contents without altering the expression of most selenoproteins in mice
Ecotoxicology and Environmental Safety Molecular mechanisms of lead-induced changes of selenium status in mice livers through interacting with selenoprotein P
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY In vivo and in vitro studies on inactivation of selenium containing protein-glutathione peroxidase 3 in mice nephrocytes caused by lead Pubmed: 32678766
Nat Immunol Selenium–GPX4 axis protects follicular helper T cells from ferroptosis 34413521
Eberhard Karls University Experimental nephrotic syndrome in mice with an inducible deletion of podocin and the role of plasminogen in sodium retention
Catalog No. Related products for research use of Sus scrofa; Porcine (Pig) Organism species Applications (RESEARCH USE ONLY!)
SEC992Po ELISA Kit for Glutathione Peroxidase 3, Plasma (GPX3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC992Po Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.