Multiplex Assay Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay)

HMG-CoA Reductase; Hydroxymethylglutaryl-CoA Reductase

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-102 86
EDTA plasma(n=5) 85-105 88
heparin plasma(n=5) 87-95 91
sodium citrate plasma(n=5) 82-95 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-96% 81-101% 92-99% 91-102%
EDTA plasma(n=5) 80-93% 81-95% 83-104% 78-88%
heparin plasma(n=5) 84-101% 82-101% 88-95% 80-90%
sodium citrate plasma(n=5) 80-104% 96-103% 97-104% 81-89%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:HMGCR) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neuroscience 27-Hydroxycholesterol contributes to disruptive effects on learning and memory by modulating cholesterol metabolism in the rat brain PubMed: 25987203
Neurotoxicology. 27-Hydroxycholesterol regulates cholesterol synthesis and transport in C6 glioma cells. pubmed:28167099
archives of medical research Transthyretin Regulated by linc00657/miR-205-5p Promoted Cholesterol Metabolism by Inducing SREBP2-HMGCR and Inhibiting LXRα-CYP7A1 Pubmed: 32241558
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPD686Ra01 Recombinant 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) Positive Control; Immunogen; SDS-PAGE; WB.
PAD686Ra01 Polyclonal Antibody to 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) WB; IHC; ICC; IP.
MAD686Ra21 Monoclonal Antibody to 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) WB; IHC; ICC; IP.
SED686Ra ELISA Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD686Ra Multiplex Assay Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.