Multiplex Assay Kit for Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay)

IL1F7; IL37; FIL1; FIL1(ZETA); FIL1Z; IL-1F7; IL-1H4; IL-1RP1; IL1H4; IL1RP1; Interleukin 37; Interleukin-1-Related Protein; Interleukin 1 Family, Member 7

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 89-104 94
heparin plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-94% 87-95% 80-105% 87-103%
EDTA plasma(n=5) 94-104% 85-101% 87-94% 88-96%
heparin plasma(n=5) 82-93% 92-101% 87-97% 92-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IL1z) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Periodontal Research Levels of interleukin-37 in gingival crevicular fluid, saliva, or plasma in periodontal disease Pubmed:25399716
Arthritis research & therapy Interleukin 37 limits monosodium urate crystal-induced innate immune responses in human and murine models of gout. pubmed:27863506
Thoracic Cancer  IL‐37 inhibits invasion and metastasis in non‐small cell lung cancer by suppressing the IL‐6/STAT3 signaling pathway Pubmed:29575809
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APE842Hu01 Active Interleukin 1 Zeta (IL1z) Cell culture; Activity Assays.
RPE842Hu01 Recombinant Interleukin 1 Zeta (IL1z) Positive Control; Immunogen; SDS-PAGE; WB.
RPE842Hu02 Recombinant Interleukin 1 Zeta (IL1z) Positive Control; Immunogen; SDS-PAGE; WB.
RPE842Hu03 Recombinant Interleukin 1 Zeta (IL1z) Positive Control; Immunogen; SDS-PAGE; WB.
APE842Hu02 Active Interleukin 1 Zeta (IL1z) Cell culture; Activity Assays.
PAE842Hu01 Polyclonal Antibody to Interleukin 1 Zeta (IL1z) WB; IHC; ICC; IP.
PAE842Hu02 Polyclonal Antibody to Interleukin 1 Zeta (IL1z) WB; IHC; ICC; IP.
LAE842Hu81 FITC-Linked Polyclonal Antibody to Interleukin 1 Zeta (IL1z) WB; IHC; ICC; IF.
LAE842Hu71 Biotin-Linked Polyclonal Antibody to Interleukin 1 Zeta (IL1z) WB; IHC; ICC.
MAE842Hu22 Monoclonal Antibody to Interleukin 1 Zeta (IL1z) WB; IHC; ICC; IP.
SEE842Hu ELISA Kit for Interleukin 1 Zeta (IL1z) Enzyme-linked immunosorbent assay for Antigen Detection.
SCE842Hu CLIA Kit for Interleukin 1 Zeta (IL1z) Chemiluminescent immunoassay for Antigen Detection.
LME842Hu Multiplex Assay Kit for Interleukin 1 Zeta (IL1z) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.